TECHNICAL DATA
MODEL
Speed*
Torque
Working cycle
Control unit
Power
Vac (Vdc)
Motor consumption
Consumption power
Capacitor
Thermoprotection
Protection degree
Dimension (L - P- H)
Weight
Working temperature
Max gate weight
Sound emission level
TECHNICAL DATA
MODEL
Speed*
Torque
Working cycle
Control unit
Power
Vac (Vdc)
Motor consumption
Consumption power
Capacitor
Thermoprotection
Protection degree
Dimension (L - P- H)
Weight
Working temperature
Max gate weight
Sound emission level
* Variable data according to gate weight
3 - PRELIMINARY CHECKS
Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the
maximum permissible operating limits specified in Fig. 2
- Check the presence and strength of the security mechanical
stops of the gate or door
- Check that the mounting area of the product is not subject to
flooding
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
starting point may be higher than under normal conditions.
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if
left in any position
SC120
cm/s
16
Nm
40
%
30
-
230
A
2,6
W
600
µF
20
°C
150
IP
44
mm
320 - 184 - 260
Kg
13,5
°C
-20 +55
Kg
1200
dB(A)
≤ 70
SC162
cm/s
16
Nm
40
%
30
CT102B
230
A
3
W
700
µF
20
°C
150
IP
44
mm
320 - 184 - 260
Kg
14,5
°C
-20 +55
Kg
1600
dB(A)
≤ 70
SC122
SC122M
16
40
30
CT102B
CT102B
230
2,6
600
20
150
44
320 - 184 - 260
320 - 184 - 260
13,5
-20 +55
-20 +55
1200
1200
≤ 70
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a
gap of contacts enabling full disconnection under the conditions
dictated by the overvoltage category III.
- Ensure that all materials used for the installation comply with
current regulations
TU11224
16
20
40
38
30
80
CT10224
230
230 (24)
2,6
1,3
600
300
20
-
150
-
44
44
320 - 184 - 260
13,5
11
-20 +55
1100
≤ 70
≤ 70
EN
13