Recoil Start
When starting the engine with the recoil start, set the toggle
switch in the "ON" position before pulling the starter handle.
1. Make sure all appliances are
disconnected from the generator.
2. For recoil start, firmly grasp the recoil
handle and pull slowly until increased
resistance is felt. Pull rapidly up and
away.
If engine fails to start after 3 pulls, or if unit shuts down during
operation, make sure unit is on a level surface and check for
proper oil level in crankcase. This unit may be equipped with a
low oil protection device. If so, oil must be checked at proper
level for engine to start and run.
Electric Start
1. Make sure all appliances are
disconnected from the generator.
2. Set the engine switch to the
middle "ON" position. Press and
hold the toggle to the "START"
position to engage the starter.
Release, set switch to
the "ON" position when engine is
running.
To prolong the life of starter components, DO NOT hold switch in
"START" position for more than 15 seconds, and pause for at least 1
minute between starting attempts.