6. Assembly and starting
Important!
You must fully assemble the appliance before
using it for the fi rst time.
6.1 Voltage
Before you use the machine, make sure that the
mains voltage complies with the specifi cations on
the rating plate. Long supply cables, extensions,
cable reels etc. cause a drop in voltage and can
impede motor start-up. In the case of low tempe-
ratures below +5°C, motor start-up is jeopardized
as a result of stiff ness.
6.2 On/Off switch (8)
To switch on the equipment set the On/Off switch
(8) to position 1.
Move the On/Off switch (8) to position 0 to switch
off the equipment.
6.3 Adjusting the pressure: (Fig. 1)
•
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
•
The set pressure can be taken from the quick-
lock coupling (5).
6.4 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar/87 psi
Switch-off pressure 8 bar/116 psi
Anl_SA_TC_AC_190_6_8_OF_SPK8.indb 24
Anl_SA_TC_AC_190_6_8_OF_SPK8.indb 24
GB
7. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the after-sales service or
similarly trained personnel to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Important!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Important!
Wait until the compressor has completely
cooled down. Risk of burns!
Important!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
8.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
•
We recommend that you clean the device
immediately each time you have finished
using it.
•
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device. The
ingress of water into an electric tool increases
the risk of an electric shock.
•
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water
Caution! To ensure a long service life of the pres-
sure vessel (2), drain off the condensed water by
opening the drainage cock (11) each time after
using. Tilt the compressor tank until the drainage
cock is at the lowest point of the tank. All the con-
densation water can then run out.
- 24 -
27.08.2019 13:54:06
27.08.2019 13:54:06