Troubleshooting Guide - EINHELL GC-SP 3580 LL Manual De Instrucciones

Ocultar thumbs Ver también para GC-SP 3580 LL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87

11. Troubleshooting guide

Faults
The equipment
does not start
The equipment
does not pump
The equipment
does not cut out
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GC_SP_3580_LL_SPK7.indb 20
Anl_GC_SP_3580_LL_SPK7.indb 20
GB
Cause
- Power supply not connected
- Floating switch does trigger
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 20 -
Remedy
- Check power supply
- Raise position of fl oating switch
- Clean intake sieve with water jet
- Unkink the hose
- Place equipment correctly on shaft
bottom
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
02.08.2016 11:42:01
02.08.2016 11:42:01

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

41.704.45

Tabla de contenido