- The pH probe removed from the pool piping.
Keep pushing the DOWN button
Push the ENTER button
Immerse the probe in the 1
Then leave the probe in the flask without touching neither the probe nor its cable (hold it by the flask).
Push the OK button
Rinse the probe with clean water and dry it out with a clean cloth (do not rub).
Immerse the probe in the 2
Then leave the probe in the flask without touching neither the probe nor its cable during 1 minute (hold
it by the flask).
Push the ENTER button
nd
Choose the 2
buffer solution pH 4 or pH 9 using the UP and DOWN buttons.
Push the OK button
displayed
The message PROBE TO BE REPLACED, ALTERED PROBE, PROBE OK may appear during this step
(informing you about the state of the probe). Anyway the pump will still be running.
After calibration of the probe, place it again on the pool's piping .
Setting of the injection mode (chemical product to be injected)
Keep pushing the DOWN button
Push the ENTER button
CHOOSE PRODUCT TO INJECT
Push the ENTER button
Choose Injection of pH minus OR Injection of Ph plus with the UP and DOWN buttons
Push the OK button
4.1.4 CALIBRATION OF THE Rx PROBE
Accessories that are compulsory to calibrate the probe :
- 1 buffer solution Rx 468 mV, provided.
- The Rx probe removed from the pool piping.
Keep pushing the DOWN button
Push the ENTER button
Choose the adequate value of the Rx buffer solution with the UP and DOWN buttons
Immerse the probe in this buffer solution, dip it then move it for about 10 seconds. Then leave the
probe in the flask without touching neither the probe nor its cable (hold it by the flask).
Push the OK button
displayed
The message PROBE TO BE REPLACED, ALTERED PROBE, PROBE OK may appear during this step
(informing you about the state of the probe). Anyway the pump will still be running.
After calibration of the probe, place it again on the pool's piping and adjust the SET POINT (requested
Rx value)
4.1.5 CHANGING THE pH SET POINT
Keep pusing the DOWN button
Push the ENTER button
Choose the adequate value with the UP and DOWN buttons
Push the OK button
4.1.6 CHANGING THE Rx SET POINT
Keep pushing the DOWN button
Push the ENTER button
Choose the adequate value with the UP and DOWN buttons
Push the OK button
100897- indB – 0209
until you reach the menu PROBE CALIBRATION.
the message Insert probe in pH 7 solution OK ? will be displayed
st
buffer solution (green one, pH7), dip it then move it for about 10 seconds.
, after 1 minute the message Calibration pH 7 OK will be displayed.
nd
buffer solution pH4 or pH9, dip it then move it for about 10 seconds.
, the message Insert probe in pH 4 OK ? will be displayed.
, after approx. 1 minute the message PROBE CALIBRATION OK will be
until you reach the menu PARAMETERS
then keep pushing the DOWN button
the message Injection of Ph minus will be displayed
to validate or CANCEL © to exit the programming step without saving.
until you reach the menu PROBE CALIBRATION.
the message Insert probe in 468 OK ? will be displayed
, after approx. 1 minute the message PROBE CALIBRATION OK will be
until you reach the menu pH ADJUSTMENT
the message Requested pH=7.2 ? will be displayed
to validate or CANCEL © to exit the programming step without saving.
until you reach the menu Rx ADJUSTMENT
the message Requested Rx =650 ? will be displayed
to validate or CANCEL
©
to exit the programming step without saving.