Descargar Imprimir esta página

Parkside PHGA 1300 A1 Instrucciones De Utilización Y De Seguridad página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
Lubricants are used inside the garden pump and domestic wa-
terworks and can contaminate the drained fluids, if the product
is improperly operated or damaged.
Warning! This electric tool generates an electromagnetic
field during operation. This field can impair active or passive
medical implants under certain conditions. In order to prevent
the risk of serious or deadly injuries, we recommend that per-
sons with medical implants consult with their physician and
the manufacturer of the medical implant prior to operating the
power tool.
Residual risks
The machine has been built according to the state-of-the-art
and the recognised technical safety requirements. However,
individual residual risks can arise during operation.
• Health hazard due to electrical power, with the use of im-
proper electrical connection cables.
• Before performing setting or maintenance work, unplug the
mains plug.
• Furthermore, despite all precautions having been met, some
non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety Instructions"
and the "Intended Use" together with the operating manual
as a whole are observed.
7. Technical data
AC motor.............................................................. 230 V∼ 50 Hz
Nominal power S3* ................................................. 1300 watts
Max. delivery flow ........................................................5000 l/h
Max. delivery height ............................................................50 m
Max. delivery pressure ....................................................... 5 bar
Max. suction height ................................................................ 8 m
Pressure and suction connection ......................................... G 1"
Max. dirt particle size .....................................................0.5 mm
Max. water temperature .................................................. 35° C
Protection class ............................................................................I
Protection category ............................................................... IPX4
Operating mode* ....................................................................S3
Weight .................................................................................12 kg
* Operating mode S3, periodic intermediate duty.
Noise
The noise values have been determined in accordance with
EN 3744.
Sound power level L
...................................................76 dB(A)
wA
Uncertainty K
.................................................................1 dB
pA/wA
Warning: Noise can have serious effects on your
m
health. If the machine noise exceeds 85 dB (A), please wear
suitable hearing protection.
8. Before commissioning
• Open the packaging and carefully remove the product.
• Remove the packaging material, as well as the packaging
and transport safety devices (if present).
• Check whether the scope of delivery is complete.
• Check the product and accessory parts for transport dam-
age. In the event of complaints the carrier must be informed
immediately. Later claims will not be recognised.
• If possible, keep the packaging until the expiry of the war-
ranty period.
• Familiarise yourself with the product by means of the operat-
ing manual before using for the first time.
• With accessories as well as wearing parts and replacement
parts use only original parts. Replacement parts can be ob-
tained from your dealer.
• When ordering please provide our article number as well as
type and year of manufacture for the product.
m DANGER!
The device and the packaging are not children's
toys! Do not let children play with plastic bags,
films or small parts! There is a danger of choking
or suffocating!
• Prior to commissioning, all covers and safety devices must be
mounted correctly.
• Before connecting the machine, make certain that the data
on the type plate matches with the mains power data.
9. Installation
m NOTE!
The garden pump and domestic waterworks can also be in-
stalled for domestic water supply indoors. To minimise vibra-
tions and noises, the garden pump and domestic waterworks
should be connected to the pipe network with flexible hoses. It
is also recommended to use anti-vibration material, e.g. to put
a rubber layer between the garden pump and domestic water-
works and the machine base. Ensure that the pump is securely
fastened using screws which fit through the screw brackets (7).
Note:
The connections for the suction and pressure connection have
been set with 1 inch at the factory. Optionally, you can use the
multifunctional adapter supplied, which offers further connec-
tion options (see point 9.1).
An additional connection system (such as a tap, hose clamp,
bayonet fitting) is required for installation and is not included in
the scope of delivery.
9.1 Function of the multifunction adapter (13)
(fig. 15 + 15a)
a. Connection (a) 1 1/4" male thread
b. Connection (b) 1" male thread
c. Hose connection (c) 1" (hose clamp is required! Not in-
cluded in the scope of delivery!)
Note:
To use connection (b), hose connection (c) must be cut off with
a knife (not included in the scope of delivery) (see cutting mark
in fig. 15)! After you have cut off the hose connection, it can
no longer be used.
Attention! Risk of cuts!
GB/IE
5

Publicidad

loading