4. If necessary, adjust the guide roller again (see "Adjusting the Guide Roller").
Tighten the hexagon screws of the shoe of the saw again.
5. Tighten the hexagon screws of the shoe of the saw again.
6. For most jobs the graduation of the scale on the shoe of the saw is accurate enough.
However, in the case of very precise angle cuts you should use an angle-measuring device! The
accuracy of the angle can be tested with a test cut into waste material.
7. In order to return the shoe of the saw to the original position, remove the mains plug from the
socket and ensure that the on and off switch is not locked in place with the locking button.
8. Release the hexagon screws of the shoe of the saw.
9. Align the shoe of the saw at an angle of approximately 90° to the saw blade and push it forwards
in the direction of the saw blade. Take care with the hexagon screws of the shoe of the saw. These
must not be covered by the shoe. If they are, pull the shoe back slightly.
10. If necessary, readjust the guide roller (see "Adjusting the Guide Roller") and tighten the hexagon
screws of the shoe of the saw again.
Setting the Number of Strokes
In order tot ensure high quality sawing it is necessary to adapt the number of strokes of the saw
blade to the material which is to be sawn. The correct speed can be set with the regulator (1). The
following table shows the ideal speed for the relevant materials:
Material
Speed
Wood
high
Metal
low
PVC, Ceramics
medium
4. MAINTENANCE
• The eye protector, air slits and motor housing should be kept as free of dust and dirt as possible.
• Rub off the device with a clean cloth or use compressed air at a low pressure to blow out any dust
or dirt. Excessive amounts of metal dust may result in electricity from the internal components
being conducted on to exposed metal parts!
• if the replacement of the supply cord is necessary, this has to be done by the manufacturer or his
agent in order to avoid a safety hazard.
Cleaning and Care
• Remove the mains plug from the socket and ensure that the on and off switch is not locked in
place with the locking button. For cleaning, use a slightly damp - but not wet -cloth! Do not use any
additional abrasive materials (petrol, turpentine etc) as these may damage the plastic housing! The
use of a mild soap is recommended! Ensure that moisture does not get into the machine! After
cleaning, wipe the device with a dry cloth!
WARNING! This machine produces an electromagnetic field during operation. This field may under
some circumstances interfere with active or passive medical implants. To reduce the risk of serious
or fatal injury, we recommend persons with medical implants to consult their physician and the
medical implant manufacturer before operating this machine.
6