Operating Instructions
Each griddle burner is tested and calibrated at the factory prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners. Please visually check the flames of the burners. Always
visually inspect your griddle before lighting. Replace any hose that is frayed or cracked. Look for anything that
could block ventilation and remove such a blockage or move the griddle. After lighting, check the flame pattern
to ensure you have even heat distribution for each burner. If burners don't light up, or if the flame pattern is uneven,
see the Troubleshooting section.
1. Read the instructions before lighting.
2. If the burner does not ignite in 5 seconds, turn the burner control knob(s) off, wait 5 minutes and repeat the
lighting procedure.
3. Inspect the gas supply hose prior to turning the gas "ON". If there is evidence of cuts, wear, or abrasion, it
must be replaced prior to use. Do not use the griddle if the odor of gas is present. Only use the pressure
regulator and hose assembly supplied with the unit.
4. Never use regulators and hose assemblies other than those supplied with the griddle. If a replacement is
necessary, contact the manufacturer to get the proper replacement. The replacement must be as per the
specifications in the Owner's Manual. DO NOT LEAVE THE GRIDDLE UNATTENDED WHILE COOKING.
LIGHTING THE BURNERS USING PIEZO IGNITION
1. Turn ALL control knobs to OFF position.
2. Turn gas supply on at LP cylinder valve or at regulator.
3. Push in control knob and turn it anti-clockwise to HI position. Push and
hold ignitor button to light the burner.
4. If the burner does not ignite, turn control knob to OFF position, wait for
5 minutes before attempting to relight the burner.
5. If the burner ignites, repeat for other burners, and turn the control knobs
to the temperature setting required for your food.
* Should the burner still fail to ignite, check the gas supply.
MANUALLY LIGHTING THE BURNERS WITH MATCH STICK
1. Turn ALL control knobs to OFF position.
2. Turn gas supply on at LP cylinder valve or at regulator.
3. Remove the cooking griddle and place the lit match close to the burner ports.
4. Push in the control knob and turn it anti-clockwise to HI position.
The burner should light immediately.
5. If the burner does not ignite, turn control knob to OFF position,
wait for 5 minutes before attempting to relight the burner.
6. If the burner ignites, repeat for other burners, and turn the control
knobs to the temperature setting required for your food.
7. Replace cooking griddle. Make sure to wear protective gloves,
such as oven mitts or BBQ gloves.
* Should the burners still fail to ignite, check the gas supply.
TURNING OFF YOUR GRIDDLE
1. Turn off the gas supply at the LP cylinder by turning the valve clockwise to a full stop.
2. Turn all burner control knobs to OFF position.
!
WARNING:
BEFORE LIGHTING
7
!