3-2 FUSE Replacement
EN
1. Set Range Switch to "OFF" position. Use a
FR
screwdriver to remove the rear cover. Take out the
malfunction fuse and replace it with a new fuse
ES
rated 0.5A / 250V (or 10A / 250V) of fast blow type.
2. Place back the rear cover and secure it with the
original screw.
For safety , use exact replacement
F1 : F0.5A / 250V 5 ×20 mm Fast blow type
F2 : F10A / 250V 6.3 ×32 mm Fast blow type
Batteries
0.5A fuse
22
WARNING
Screw
10A fuse
4. MAINTENANCE
To avoid electric shock, remove the test leads
before opening the case, and close the case
before using the meter.
To prevent fire and possible arc-flash, use
fuses with ratings shown on the back of the
meter.
To avoid contamination or static damage, do
not touch the circuit board without proper
static protection.
Screw
WARNING
CAUTION