This appliance generates heat.
The kettle switches off automatically when water boils. You can
switch the kettle off before water boils using a switch. When the
kettle switches off automatically (or when it was switched off man-
ually), it may take some time (approximately 15 ­ 20 seconds to cool
down) to be ready for re­use.
The kettle must only be used with the supplied base.
Do not touch the surface marked with this symbol. Do not
touch the surfaces during or after operation of the appliance.
These surfaces are hot.
Unplug the kettle from the power outlet and wait until it cools down
before cleaning.
When boiling the water, parts of the kettle made of stainless steel
become very hot.
Do not switch on the kettle without an adequate amount of water
(level marked as "min" on the scale).
Do not leave the kettle unattended, and when not completely
cooled down.
Use only the handle to move the kettle, other external parts may
be hot.
Use the appliance on a flat and stable surface.
Make sure that the voltage indicated on the nameplate corresponds
to that of your home electrical mains. Alternating current must be
used, typically marked ~.
This appliance is intended for use at home or in facilities, such as
kitchen for employees; in shops, offices and other working environ-
ments, use by the customers of hotels, motels and other residential
facilities, in rural residential buildings, in the accommodation facil-
ities.
SPECIFICATION:
Power specification:
Power rating:
Capacity:
CONTROL PANEL:
1. On/Off
2. BOIL indicator
3. KEEP WARM indicator
4. Temperature setting button: 40, 50, 60, 70, 80, 90 and 100°C
5. Temperature display
5
2
1
4
1. Two touch sensors (boil / keep warm)
a.
ON/OFF touch sensor: touch sensor: Touch the ON/OFF sensor
to start heating water. The default setting for the water temperature
is 100°C.
Press and hold for approximately 3 seconds to switch to
the keep warm mode.
b. Set temperature touch sensor: Touch the set temperature sensor
to select the temperature that suits your needs.
2. Indicator
a. Temperature display
the actual temperature of the water in the kettle. In keep­warm
EN
AC 220­240V / 50­60Hz
1850­2200W
1.5l
3
: In the water boiling mode, it displays
mode, it displays the kettle's set temperature;
b. The water boiling indicator lights up when the kettle is in water
boiling mode.
c. Keep Warm Indicator lights up when the kettle is in Keep Warm
mode.
3. Operate the appliance
When you turn on the kettle, the boil water indicator, keep warm
indicator and temperature indicator flash and the appliance beeps
twice. Then the water boiling and keep warm indicators turn off and
the temperature indicator stays on. The kettle displays the current
water temperature.
4. Water boiling function
a. Boil the water: when the appliance is plugged in, touch the ON/
OFF sensor to directly use the 100°C water boiling mode.
When heating starts, the appliance beeps and the boiling indicator
lights up. When the water temperature in the kettle reaches 100°C,
the appliance beeps twice and the water boiling indicator will turn
off. The kettle will turn off automatically.
b. Select the temperature to heat the water: when the appliance is
plugged in, touch the Set temperature sensor to adjust the temper-
ature to your needs. Then touch the On / Off sensor. The kettle turns
on and the boiling indicator lights up. When the desired tempera-
ture is reached, the kettle turns off. When you touch the On / Off
sensor while in the keep warm mode, the kettle will turn off.
5. The Keep Warm function
When the appliance is plugged in, touch the "Set Temperature"
sensor to select one of the 7 temperatures 40°C, 50°C, 60°C, 70°C,
80°C or 90°C (Keep Warm feature is not available for the 100°C set-
ting). Once you have selected the desired temperature, touch and
hold the ON / OFF sensor for approximately 3 seconds and the keep
warm indicator will flash 5 times. Once it is on, the water begins to
boil. When the water temperature in the kettle reaches the set tem-
perature, the appliance will beep twice and the appliance turns off.
The kettle cools down. When the temperature drops enough, the
kettle starts heating water again. It stops heating the water when it
reaches the set temperature. The cycle begins again. During the cy-
cle, the keep warm indicator is always on and the boiling water indi-
cator is off. If the initial water temperature poured into the kettle is
higher than the set temperature, then the keep warm indicator will
flash 5 times. Then it stops flashing. Beep sounds 5 times as a special
reminder. The kettle cools down to the set temperature and then
starts to heats the water. Keep warm time: Keep warm cycle con-
tinues for 2 hours and then the appliance and the indicator turn off.
6. Time and temperature
The water temperature display accuracy is ±5°C (for at least 0.5l of
water in the kettle). Temperature display accuracy is lower for less
water.
7. Turn off the appliance
Touch the On / Off sensor at any time. The appliance and indicators
will turn off. The temperature indicator continues to show temper-
ature. The temperature indicator turns off after about 20 minutes.
8. Memory feature
The keep warm mode has a memory function. If the water temper-
ature in the kettle is higher than the keep warm temperature the
keep warm function continue to operate. If the water temperature
in the kettle is lower than the set keep warm temperature, the ap-
pliance will turn off.
Note! Figures are for illustrative purposes only. Individual models