RELAY OUTPUT
Function: select the command which activates the Relay output for the audio/video module
Lock-release: every lock-release command activates the output
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
Call sent: every call sent activates the output
Activation
Local output control (non-editable)
Output
Relay (non-editable)
Enable Tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
VIRTUAL OUTPUT 1 / VIRTUAL OUTPUT 2
Function: select the command which activates the virtual output for the audio/video module. The virtual
outputs are NOT physically part of the module, they are commands sent over the bus.
Lock-release: every lock-release command activates the output
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
Call sent: every call sent activates the output
Activation
Local output control: activates the output set in the "Output" field (SE output for the module or Relay
output for the module)
Control on Ultra bus (UDB): the command activates the relay on the Module keypad specified in the
"Type" field (Output: Relay 1 or Relay 2)
Actuator control: the command activates the actuator with the address entered in the "Address" field
Enable tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
EVENTS
You can set the several functions to be executed when specific events occur. Up to 20 events can be set.
EVENTS
No.: select the progressive number of the event
Action: select the action triggering the event
None: no action (default)
Self activation: if a door entry monitor with an address that falls within the values entered in the "From
address" and "To address" fields performs a self activation, it triggers the event specified in the
"Activation" field
Call sent: if a call is sent to a door entry monitor with an address that falls within the values entered in
the "From address" and "To address" fields, it triggers the event specified in the "Activation" field
Lock-release: if a lock-release command is sent from a door entry monitor with an address that falls
within the values entered in the "From address" and "To address" fields, it triggers the event specified
in the "Activation" field
Actuator control: if an actuator command is sent with an address that falls within the values entered in
the "From address" and "To address" fields, it triggers the event specified in the "Activation" field
Activation: action triggered after the event specified in the "Action" field occurs
Local output control: activates the output set in the "Output" field (SE output for the module or Relay
output for the module). NOTE: Module SE Output and/or module Relay Output must be set in the menu
"Outputs" > SE Output and/or Relay Output with "Function" > Lock-release and/or actuator
Control on Ultra bus (UDB): activates the relay on the number keypad specified in the "Type" field
(Relay 1 or Relay 2)
Actuator control: activates the actuator with the address specified in the "Actuator address" field
(from 1 to 255)