INTRODUCTION
t
his unit is intended fOr prOfessiOnal use
r
ead all the instructiOns in this manual priOr tO use
• The 24785, 24795 meter is an oval gear model.
• Only use the unit for the purposes for which it is intended.
• This unit has not been approved for use in commercial transac-
tions.
• Do not alter or modify the unit.
• Do not exceed the maximum unit working pressure. See page 7,
technical specifications.
INSTALLATION
The meter can be connected to a control gun or installed directly in
the distribution line pipe.
It is recommendable to install a cut-off valve before the meter to
facilitate its maintenance or repair.
The meter has a ½" NPSM connection at the inlet and outlet.
It also includes an inlet flange and a flange at the outlet with
BATTERIES
The location of the batteries is shown in the following figure:
CHARGING STATUS OF THE BATTERIES
The meter shows the charging status of the batteries on the display.
If the meter does not switch on when pressing the ON/RESET button, or switches off after being pressed, replace the batteries with new ones.
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
2
WARNING
.
BATTERIES OK
• Use the unit with fluids and solutions which are compatible with
the moist parts of the unit. See the relevant section of the tech-
.
nical specifications.
• Observe the manufacturer's safety warnings for the fluids used.
• The meter has been manufactured with low tolerances in order to
ensure high precision over a wide range of flows and viscosity.
• Check measurement units counter before first use.
• In order to save energy the meter switches off automatically af-
ter 30 seconds of inactivity. All the data are stored for recovery
once the meter has been restarted.
seating for an O-ring seal which enables connection for the range
of guns and original Orion accessories.
The meter requires two 1.5 V batteries and size LR 03 as the power
supply source. They are housed in a support which, in conjunction
with the lid design, prevents the batteries from being removed
accidentally in the event of impacts or vibrations.
indicated On the batteries when installing
When replacing the batteries the monitor briefly displays the meter
software version.
BATTERIES HALF CHARGED
WARNING
O
bserve the pOlarity
BATTERIES EMPTY
REPLACE THE BATTERIES
.