Function overview
• Charger for 1–4 AAA size batteries, AA size
batteries, C size batteries or D size batteries, as
well as a 9 V E-block
• Reverse polarity protection
• Pulsed float charging
• Capacitance measurement in mAh/ah
• Individual querying of current parameters:
Voltage (V); capacity (mAh/Ah); time (hh:mm);
current (mA)
• Multiple over-charging protection per battery
and automatic termination of charging process
• Battery defect & alkaline detection
With round cells:
• Adjustable charging currents per charging slot:
400 mA, 600 mA, 800 mA when charging
1-4 batteries; 400 mA, 600 mA, 800 mA,
1,500 mA, 1,800 mA when charging 1-2 bat-
teries with the outer charging slots.
Technical Data
Charger
Art. 0827 400 5
Cordless systems
Ni-Cd / Ni-MH
Input voltage of ex-
100 - 240 V AC /
ternal power pack
50 - 60 Hz
Car adapter input
12 V DC
voltage
Input voltage of
12 V DC
charger
Charging current for
400 mA – 1800 mA
round cells
Charging current for
15 mA
9 V E-block
Maximum charge-
11000 mAh with round cells
able capacitance
300 mAh with 9 V block
batteries
Start-up
Operation with power pack
Place the mains plug over both mains contacts
■
(step
and
).
Insert the mains plug into the guide as far as it
■
will go (step
).
The mains plug must engage audibly
■
when pushed in.
Connect the hollow plug [8] of the mains power
■
pack [7] to the hollow plug socket [6].
Connect the mains power pack [7] to the mains
■
power supply (100-240 V AC 50-60 Hz).
3 The charger is ready for operation.
Operation with car adapter (Fig. I)
Connect the hollow plug [8] of the cigarette
■
lighter plug [9] to the hollow plug socket [6].
Connect the cigarette lighter plug [9] to the
■
cigarette lighter socket (12 V DC).
3 The charger is ready for operation.
LC display (Fig I)
Display:
Charger is connected to the power
„- - -"
supply. There is no battery in the
charging slot.
Is displayed during the first charge
„- - - mAh"
with the "TEST" charging program.
Charging process is finished. The
„Full"
battery is supplied with a float
charge.
Once the "TEST" and "REFRESH"
charging programs have finished,
the display switches between
"Full" and the measured discharge
capacity.
„ERR"
Is alternately displayed when:
and „Lo"
— The battery has an internal short-
circuit and is defective.
No charging is taking place.
Is alternately displayed when:
„ERR"
— The battery is very high imped-
and „Hi"
ance.
— There is a non-rechargeable bat-
tery in the charging slot.
No charging is taking place.
9