General technical data - 2 pipe system (CC2)
VENS - Standard AC fan
Size
Cooling
Cooling capacity
(1)
Sensible capacity
(1)
Total power input
(1)
Heating
Heating capacity
(2)
Internal exchanger
Number of rows
Water volume
Water flow-rate
(1)
Water pressure drops
(1)
Water pressure drops
(2)
Air handling section fans (supply)
Type of fans
(3)
Number of fans
Air flow
(4)
Air flow
(4)
Max external static pressure
Connections
Water fittings
Condensate drain
(5)
Noise levels
Sound pressure level (1m)
(6)
Sound power Level
(6)
Power supply
Power supply STD
(1) Indoor air at 27°C D.B/19 C W.B
Water temperature in / out 7°C / 12°C
Air flow at maximum speed (ESP = 0Pa)
(2) Indoor air temperature at 20°C
Water inlet 70°C and outlet 60°C
Air flow at maximum speed (ESP = 0Pa)

Operating range

2 pipe system (CC2) and 4 pipe system (CC4)
Size
Heating
Max water inlet temperature
Max water inlet temperature
Max. air inlet temperature (D.B.)
Max. air inlet temperature (D.B.)
Cooling
Max. air inlet temperature (WB)
Min air inlet temperature (W.B.)
Max water side pressure
Max water side pressure = Coil max pressure. In presence of accessories (for example 2-3 way valves) the max water side pressure is 15 bar.
003.0
005.0
[kW]
1,5
2,0
[kW]
1,29
1,62
[kW]
0,055
0,055
[kW]
3,74
4,91
[Nr]
3
3
[l]
0,69
0,7
[l/s]
0,07
0,1
[kPa]
13,1
16,3
[kPa]
15,9
19,2
CFG
CFG
[Nr]
1
1
[l/s]
103
111
[m
/h]
370
400
3
[Pa]
86
86
["]
1/2" F
1/2" F
[mm]
20
20
[dB(A)]
44
44
[dB(A)]
55
55
[V]
230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
003.0
005.0
007.0
[°C]
80
80
80
[°C]
2
2
2
[°C]
40
40
40
[°C]
2
2
2
[°C]
40
40
40
[°C]
2
2
2
[bar]
30
30
30
007.0
009.0
011.0
015.0
2,53
3,02
3,75
4,25
2,07
2,31
2,87
3,23
0,085
0,085
0,075
0,075
5,98
6,71
8,16
9,44
3
3
3
3
0,99
1,01
1,3
1,31
0,12
0,14
0,18
0,2
18,5
20,8
22,6
24,1
20,1
20
20,9
23,2
CFG
CFG
CFG
CFG
1
1
2
2
139
153
186
200
500
550
670
720
86
86
98
98
1/2" F
1/2" F
1/2" F
1/2" F
20
20
20
20
50
51
43
43
61
62
54
54
(3) CFG = AC centrifugal fan
(4) Air flow at maximum speed - (ESP = 0Pa)
(5) Intended as an external diameter
(6) The sound pressure level is measured 1 m from the external surface of the wall mounted in view unit, for the
built-in it is possible a sound pressure reduction of 2 dB or higher. The determination of the sound pressure levels has
been made with respect to the UNI-EN-ISO 3744 certification.
009.0
011.0
015.0
80
80
80
2
2
2
40
40
40
2
2
2
40
40
40
2
2
2
30
30
30
017.0
021.0
025.0
5,52
6,42
7,53
4,33
4,80
5,67
0,145
0,145
0,175
12,0
13,3
15,5
3
3
3
1,6
1,62
1,91
0,26
0,31
0,36
24,5
27,1
28,8
22,6
22,7
23,8
CFG
CFG
CFG
2
2
2
278
292
356
1000
1050
1280
103
103
113
1/2" F
1/2" F
1/2" F
20
20
20
49
51
54
60
62
65
017.0
021.0
025.0
80
80
80
2
2
2
40
40
40
2
2
2
40
40
40
2
2
2
30
30
30
031.0
041.0
051.0
9,02
9,6
10,71
6,62
7,64
8,36
0,175
0,285
0,285
18,1
21,1
23,2
3
3
3
1,92
2,21
2,23
0,43
0,46
0,51
29,2
31
33,4
22,9
29,2
30,6
CFG
CFG
CFG
2
3
3
364
531
539
1310
1910
1940
113
119
119
1/2" F
1/2" F
1/2" F
20
20
20
55
57
57
66
68
68
031.0
041.0
051.0
80
80
80
2
2
2
40
40
40
2
2
2
40
40
40
2
2
2
30
30
30

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elfospace out-hElfospace in-vElfospace in-h

Tabla de contenido