The Automatic–Manual Selector should always be in the automatic position when the kit is
operating normally, otherwise the digital system will commit errors which could lead to
significant damage of the equipment.
The filter is the filtering element. Water passes through the sand which retains the particles.
The selector valve should be in the FILTERING position for the filter to operate.

4.3. EMPTYING THE SPA

The compact equipment can empty the Spa. To do this, follow these steps:
- Open the valves of the circuits that by-pass water to the drain.
- Turn off the Filtering Pump by placing the selector in the OFF position.
- Place the selector valve in the EMPTYING position.
- Turn on the Filtering Pump by placing the selector in the Manual position.
- Once the Spa is empty, turn off the filtering pump by placing the selector in the OFF position
and disconnect the equipment from the power supply.
- To refill the spa, place the valves in their normal position.
When the water level in the Spa is insufficient for the pump to suck water, must shut the
pump by turning the selector to the OFF position. If the pump works without water would
suffer major damage. Emptying will drain through.
VERY IMPORTANT