ASSEMBLY
Assembly and Installation
Remove all parts from the packaging and check they are not damaged. If you see, or suspect a fault, do not use, contact your
dealer immediately.
Product Assembly
Slide each armrest into the locating tubes on the seat assembly until the spring button clips "snap" into position. Slide the moun-
ting frame into the locating tubes on the seat assembly, note the frame is width adjustable, and choose the correct width to suit
your bath. Please refer to the instruction for correct fitting.
Assembling to a bath
Place the seat onto flat bath ledges.
*NOTE: All the mounting frame feet must rest on the flat sides of the bath.
If necessary extend the mounting frame by removing the fixing e-clips, adjusting the width of the frame so that it is closest to the
external width of the bath and replacing the clips, check they are all replaced and secured correctly.
Secure the mounting frame using the clamps under the seat by turning the hand wheels until secure against the walls of the bath
on both sides.
Check the frame is secure, but do not over tighten as this could damage the bath.
*NOTE: If the seat is removed and replaced over the bath, it is important the fixing clamps are re-adjusted and tightened as de-
tailed above.
USE
1. Raise the locking handle and rotate until the seat is facing the user, lower the handle and lock into position.
2. Transfer user into seat, raise locking handle and rotate slowly into bath, taking care when raising legs over the side of the
bath.
3. Ensure seat is locked into position and no longer rotates freely before starting to wash.
CARE AND MAINTENANCE
Failure to care for and monitor your product may result in the risk of serious injury.
Wipe the product dry after each use.
Periodically clean the bath seat with a damp cloth and a mild detergent or disinfectant. For example, a mild chloride-
based disinfectant can be used.
The bath seat can also be cleaned in an aqueous system up to 80ºC.
Check that the bath seat swivels easily, smoothly and locks into place. If the locking mechanism does not seem positive
or if there is excessive movement in the unit, remove it from service and contact your dealer.
Check the bather for cracks and damage, particularly to the seat and plastic tube.
Do not use in environments above 60ºC (e.g. saunas).
In case of malfunction, do not repair the product yourself. Consult an authorised dealer.
Checklist :
To keep the product in good condition, check before each use, and check regularly as follows:
Check the article
Check the operation of the spring loaded knob to allow 90° rotation of
the product
Check the condition of the seat and the armrests
Check the function of the anti-slip screws
Check that the brackets are fully attached to the edges of the bathtub
Version Mai 2023
Anytime
Weekly
X
X
X
X
7