Troubleshooting Tips - Nemaxx BT55X Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
KEN001BT55X

TROUBLESHOOTING TIPS

1. If the dehumidifier fails to work, please switch off the unit immediately, and pull out the
plug and check the following:
Problem
Device does not work
The motor works, the
compressor doesn't
work.
The motor doesn't work
Possible causes
Power cut or the plug is broken.
The plug doesn't insert well.
Power voltage too low
(supply voltage < Rated voltage 20%)
The cable is too thin
The system temp. is too high, device stops
for protection.
The indicator humidity control / temp.
protection light on
The system temp. is too high, device stops for
protection.
Set humidity > environment humidity,
device auto stops, the indicator humidity
control / temp. protect is on.
Water tank is full.
Compressor over loading.
Compressor burnt due to leakage or voltage
too low.
Something wrong with the circuit board.
Device is defrosting.
DEFROST indicator light is on
Compressor capacitance invalid.
The motor is broken.
Something is wrong with the circuit board.
EN
What to dot
Check the power supply.
Insert the plug properly
Wait until the supply voltage normal
Change the cable.
Repress the ON/OFF button.
When ambient humidity > set
humidity, device auto start.
Pour out the water, put the bucket
back.
Press ON/OFF button or contact
qualified professional.
Please contact qualified
professional.
Change the circuit board.
Wait until defrosting finished.
Change the capacitor.
Change the motor.
Change the circuit board.
12
Version: 4.0
28.08.2017

Publicidad

Tabla de contenido
loading

Productos relacionados para Nemaxx BT55X

Tabla de contenido