Nemaxx BT55X Instrucciones De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
KEN001BT55X
TROUBLESHOOTING TIPS
Problem
Low motor
Dehumidi-
speed, low
fying
temp. of
capacity
the outlet
limited
air.
Dehumidifying capacity
is low.
Working for a long
time, but the room is
still humid.
Too noisy
Water leakage
2. If you can't solve the problem according to the method, please contact qualified
professional.
3. It is normal that the device has the circulation sound of the refrigerant.
4. It is normal that the warm air blows out from the outlet.
Possible causes
The capacitance of the fan motor and
compressor are reduced.
The refrigerant is leaking.
The filter is very dirty, or there are some
objects in the outlet or inlet.
The humidity or temp. is too low.
More than two devices working in the
same room.
The door or the window is open.
There is water vapor source in the room. Please close the water vapor source.
Room space is too big.
Specification of the dehumidifier is too
small.
If the ground is rugged?
The device isn't in right position.
Using in cold weather, device defrosting
repeatedly and the ice near the water
outlet haven't melted completely and plug
up the draining hose.
If the draining hose is clogged by some
objects.
If the draining hose installed incorrectly.
EN
What to dot
Change the capacitor.
Please contact qualified professional.
Clean the filter and remove the objects.
It is recommended to stop the device.
It is recommended to using one device.
Please close the door and the window.
Adjust the space or choose larger
capacity dehumidifier.
Please choose a dehumidifier with larger
capacity.
Make adjustment.
Put it in right position.
Please stop the device regularly, make
sure the ice melts completely.
Clean the draining hose.
Install the draining hose correctly.