Descargar Imprimir esta página

Qlima SRE3230TC Instrucciones De Uso página 66

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Only the use of the
correct fuel will ensure
safe, efficient, and
comfortable use of your
heater.
This transportation cap
is packed separately in
the box. Only this cap
ensures trouble-free
transportation of the
heater after use.
Store it well!
4
66
All manuals and user guides at all-guides.com
what you need to know in advance
vENTILATE SUFFICIENTLy
Read this user manual carefully before using the appliance and keep it for future
reference. Install this device only when it complies with local/national legislation,
ordinances and standards. This product is intended to be used as a heater in
residential houses and is only suitable for use in dry locations, in normal household
conditions, indoors in living room, kitchen and garage.
Regardless of the model, you must always make sure that the heater is used in
a room large enough to enable the heater to be used safely without extra
ventilation. If the room is smaller than required, you must always open a door or
window slightly (ensuring an opening of approx. 2.5 cm). It is important that every
room where the heater is used has sufficient air intake and efficient air outflow
(both openings must have a minimum cross section of 50 cm
to the safety system are allowed, as that will invalidate the guarantee that the air
probe will work properly. Consult your dealer in case of doubt.
Especially for France: Your heater was designed to operate exclusively on fuel for
liquid fuel-operated mobile heaters in accordance with the Decrees of 18-07-2002
and 25-06-2010. The use of other fuels is forbidden.
Ask your dealer or check our website for the addresses of our retailers.
The liquid fuel-operated mobile heater is intended as an extra heater, and not as a
continuous source of heat.
Especially for United Kingdom: Only use Class C1 paraffin fuel in accordance with
BS2869; Part 2, or equivalent.
The user must comply with the following instructions for proper use:
DO NOT
- use the liquid fuel-operated mobile heater in caravans, boats, and vehicle cabins;
- use the liquid fuel-operated mobile heater in insufficiently ventilated rooms
(consult the table of properties for the minimum dimensions of the room to be
heated), underground rooms and / or at a height of over 1500 metres;
- modify the heater safety features.
The use of this type of heating in public rooms is subject to prior regulatory
permission. Obtain proper information on this in advance.
THE RIGHT FUEL
Your heater has been designed for use with high-quality water-free pure paraffin
oil, such as Qlima Premium Quality Fuels. Only fuels of this kind will ensure clean
and proper burning. Lower quality fuel may result in:
E
increased possibility of malfunctioning
E
incomplete combustion
E
reduced heater lifetime
E
smoke and/or fumes
E
deposits on the grid or mantle
Using the right fuel is therefore essential for safe, efficient, and comfortable use
of your heater.
Damage and/or malfunctions of the heater due to the use of other than high-
quality water-free pure parafine oil is not covered by the warranty.
Always refer to your local dealer for the right fuel for your heater.
). No modifications
2

Publicidad

loading

Este manual también es adecuado para:

Sre3531tcSre3631tc