ADAPTING BLOWER FOR
B5.
OUTSIDE BACK EXHAUST
1 Remove the two screws that hold the blower plate
and remove the screw holding the blower motor to
the oven. Slide blower plate from under its retaining
flange.
Retaining
Flange
2
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
BEFORE: Fan Blade
Openings Facing Up
3 Rotate blower unit counterclockwise 180°.
Before Rotation
Back of
Oven
4
Roll the blower unit 90° so that fan blade
openings are facing out the back of the oven.
Before Rolling
Back of
Oven
Installation Instructions
Blower Plate
Back
of Oven
After Rotation
Back of
Oven
After Rolling
Back of
Oven
5
Place the blower unit back into the opening.
AFTER: Fan
Blade Openings
Facing Back
CAUTION: Do not pull or stretch the blower unit
wiring. Make sure the wires are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
6
Replace the blower plate in the same position
as before and replace the screws for the blower
plate and blower motor.
Blower Plate Screws
17
Blower Plate
Back of Oven
Blower Motor Screw