Storage
Data tag information is very important
if you need help from
our Customer Service Department or an authorized service
dealer.
The data tag (Figure 9) is located on the engine support on
the muffler side of the generator_ For future reference, please
copy the model, revision, and serial number of the generator
in the space below.
MODEL
REV NO
"_
SERIAL
AC VOLTS
]
ACAMPS
]
AC WATTS
]
DC VOLTS
]
DCAMPS
[
]
Single Phase / 60 Hz/ 3600 RPM
Rated at 40 C / Class F Insulation
Troy_Bilt@ is a registered trademark of
MTD and is used under license to
Bnggs & Stratton
Power Products Group, LLC
Jefferson, Wl
888-611-6708
Copy Revision
Here
Copy Serial
Number Here
The generator
should be started at least once every seven
days and allowed to run at Heas[ 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.
Generator
Storage
° Clean
the generator
as oudined
in "Generator
Cleaning'.
, Check
that
cooling
air slots
and openings
on generator
are open and unobstructed.
WARNING
DO NOT place a storage cover over a hot generator.
Let equipment
cool for" a sufficient
time before placing the
cover on the equipment.
Engine
Storage
See engine
owner's
manual
for instructions.
Other
Storage
Tips
° To prevent
gum from
forming
in fuel system
or on
essential
carburetor
parts, add fuel stabilizer
into
fuel
tank
and fill with
fresh
fuel. Run the unit
for several
minutes
to circulate
the additive
through
the carburetor.
The
unit and fuel can then
be stored
for up to
24 months.
Fuel stabilizer
can be purchased
locally.
° DO
NOT
store
fuel from
one season
to another
unless
it has been
treated
as described
above.
° Replace
fuel container
if it starts
to rust.
Rust and/or
dirt
in fuel can cause problems
if it's used with
this unit.
, Store
unit in a clean and dry area.