EN
Translation
Information on this document
The operating manual (operation and installation) is part of the product and must be downloaded, read and
understood before installation and initial use. The current manuals can be downloaded directly from our homepage:
www.keba.com/emobility-downloads
The downloaded manuals must be kept for the entire life of the product. If you require the information in another
language, please contact your customer advisor.
In addition to the safety notes in this manual, the applicable safety and accident prevention regulations for the
application must be observed.
Safety notes
WARNING
!
Risk of death due to electric shock and fire hazard!
The device may only be installed and operated in perfect condition.
A damaged device must be taken out of commission and repaired or replaced by a qualified and authorized
electrician.
Repairs may only be made to the device by trained service technicians with replacement parts approved by
the manufacturer and checked before installation.
The device does not have its own cut-off from the power supply. A suitable cut-off device (e.g. circuit breaker,
cut-off switch or equivalent means of disconnection) must be provided as part of the electrical system of the
building. To interrupt the power supply, always use the designated cut-off device.
The device must be protected by a residual current circuit breaker (at least type A).
No unauthorized conversion work or modifications may be done to the device.
No markings (such as safety signs, warnings, wire markings, etc.) may be removed from the device.
The device must be regularly checked for damage, defects, deterioration and dirt.
When installing the device, the following additional notes must be observed:
Installation, commissioning, maintenance or retrofitting of the device must be performed by correctly trained,
qualified and authorized electricians
installation regulations
For installation on hollow walls, at least two mounting screws must be secured to a support element of the
wall. Special hollow-wall anchors must be used for other mounting screws. It is particularly important to make
sure the substructure has sufficient load-bearing capacity.
For the Ethernet connection (LAN), only voltages and circuits are permitted to be connected which have a safe
separation from hazardous voltages (for example sufficient insulation).
The connection panel is never permitted to be left open unattended. Before leaving the device, the connection
panel cover must be mounted.
Compensation currents flowing through shielding in extended systems can lead to damage to the interfaces
and hazards when working on the data lines. Any measures (such as connecting to a shared distribution
board, expanding a TN-S network, etc.) should be discussed with the person responsible for building services.
(1)
Persons who, due to their special training, expertise and experience as well as knowledge of current standards, are able to
assess the work performed and the possible hazards.
(2)
Please note that additional overvoltage protection may be required by national regulations.
1
!
(1)
who are fully responsible for the compliance with existing standards and