INFORMATION CODES
Information codes may be displayed to help you better understand what is occurring with your washer.
CODE SYMBOL MEANING
dc
dL
dS
FL
Hr
LE
LO
nd
nF
nF1
Sr
WF350AN-02833A-04_EN.indd Sec6:31
WF350AN-02833A-04_EN.indd Sec6:31
Unbalanced load prevented your
washer from spinning.
Door is unlocked when washer is
running.
Door is open when washer is
running.
Your washer failed to lock the
door.
Water temperature control
problem.
(Heater control problem)
Your washer has tried to fi ll but
has not reached the proper water
level.
The door will not unlock.
Your washer is not draining.
It can also mean that the unit
senses a small clog while draining.
Your washer has tried to fi ll but
was unsuccessful.
Check if the hot water supply
hose is connected.
The hot/cold water hose
connection is not correct.
Problem with control.
SOLUTION
Redistribute the load, press the Start/Pause
button.
Press the Power button to turn off your washer,
then restart the cycle. If the code reappears, call
for service.
Close the door tightly and restart the cycle.
If the code reappears, call for service.
Close the door tightly and restart the cycle.
If the code reappears, call for service.
Call for service.
Call for service.
Make sure the door is fi rmly closed.
Press the Power button to turn off your washer,
then turn it on again. If the code reappears, call
for service.
First of all, clean up the drain fi lter. Then
check the following.
Clean the fi lter (See page 26).
or
1. Turn off the unit for 10 seconds and then turn
it on again.
2. Select the Spin Only cycle (See page 19).
3. Press the Start/Pause to drain the water.
If it still does not drain, call for service.
Make sure the water faucets are open all the
way. Check for kinked hoses.
Check the inlet screens on the fi ll hoses.
If you use a Flood Safety Device, then please
remove the device and connect the water hoses
directly to the unit.
You must connect the hot water supply hose
because hot water is supplied by the Auto
Temperature Control (A.T.C.) function if the
temperature of the cold water is lower than 59°F.
Please connect the hot/cold water hose
connection correctly.
Call for service.
cycle chart _31