Descargar Imprimir esta página

Hatco HXMH Serie Instrucciones Originales página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

Flip-Up Doors
Flip-up doors are available for all models as an added option at
the time of order. Flip-up doors can be installed on each shelf
on either the customer side or operator side of the unit. Use the
following procedure to install flip-up doors (the procedure is the
same for either side as well as each shelf).
1. Align the screw holes at each end of the flip-up door hinge
with the mounting hole in each end plate on the unit.
2. Insert a hinge screw through each end plate and into the
flip-up door.
3. Tighten the hinge screws until the flip-up door is secure.
Do not over-tighten the screws.
Mounting
Hole
Flip-Up Door Installation
Sneeze Guards
Sneeze guards are available on the customer side for all models as
an added option at the time of order. Sneeze guards are installed
by re-positioning flip-up doors and securing with a bracket.
1. Install the flip-up door. Refer to "Flip-Up Doors" in this section.
2. Remove the two screws from the end plate on each side
of the unit.
3. Rotate up and hold the flip-up door in the sneeze guard
position.
4. Align the holes on one of the sneeze guard brackets with
the end plate screw holes and slide the bracket onto the
flip-up door.
5. Install the end plate screws through the sneeze guard
bracket and into the end plate. Tighten securely.
6. Repeat steps 2–5 on the other side of the unit.
Sneeze Guard Installation
Form No. HXMCEM1-0417
Hinge
Screw
Hinge
Flip-Up Door
End Plate Screw
Sneeze Guard
Bracket
Flip-up door
rotated to
sneeze guard
position.
OPTIONS AND ACCESSORIES
Digital Temperature Controller
Units may be equipped with optional digital temperature
controllers that regulates and displays the base temperature(s).
Use the following procedures to operate the digital temperature
controller.
NOTE: This option is factory installed only, not available for
retrofit.
NOTE: Units manufactured for use outside the United States
and Canada will have digital temperature controllers
that indicate temperature in Celsius (°C).
"out 1"
SET
Down Arrow
Key
Digital Temperature Controller
1. Move the unit Power I/O (on/off) switch(es) to the I (on)
position.
• The digital temperature controller will energize and the
current temperature of the heated base(s) will appear
on the display. CAUTION! Some exterior surfaces
on the unit will get hot. Use caution when touching
these areas.
• The phrase "out 1" will appear in the upper left corner of
the display to show that the base is in heat mode.
2. Press and release the
temperature will be shown on the display and "out 1" will
flash in the upper left corner.
3. Press the
key or
change the setpoint temperature. If no key is pressed
within 15 seconds, the display will revert to the current
temperature of the heated base(s).
4. Press the
key or wait 15 seconds to lock in the new
setpoint temperature. The setpoint temperature range of
the controller is from room temperature to the maximum
operating temperature of the unit.
Locking/Unlocking the Digital Temperature
Controller
The keys on the digital temperature controller can be locked to
prevent unauthorized changes to the settings.
To lock the keys of the digital temperature controller:
• Press and hold both the
same time for over two seconds. The message "Loc" will
appear on the display.
To unlock the keys of the digital temperature controller:
• Press and hold both the
same time until the message "UnL" appears on the display.
13
Celsius
Symbol
Up Arrow
Key
Key
key. The current setpoint
key within 15 seconds to
key and
key at the
key and
key at the

Publicidad

loading