Descargar Imprimir esta página

Whirlpool WOEC3030L Guia página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

DIMENSION GUIDE
Flush Installation
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 1/4" (6 mm) reveal on the top, a
1/4" (6 mm) reveal on the sides, and a 1/8" (3 mm) reveal on the
bottom of the wall oven.
The front face of the cleats and platform will be visible and
should be treated as a finished surface.
FRONT VIEW
B
D
E
F
G
H
30" (76.2 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 30
" (76.8 cm) minimum width of flush inset cutout
1
4
C. 28
" (73.3 cm) minimum width of opening
7
8
D. 43" (109.2 cm) minimum height of flush inset cutout
E. 42
" (107.9 cm) recommended cutout height
1
2
F. 11/16" (1.7 cm) side cleat*
G. 1/4" (0.6 cm) spacer the entire depth of the cutout*
H. Recommended junction box location
I.
4
5
"-19
1
" (11.7-48.9 cm) bottom of cutout to floor
8
4
J. 25" (63.5 cm) minimum depth of cutout
*Cleats and spacers must be recessed 1
front of the cabinet
.
SIDE VIEW
A
C
F
G
J
H
I
" (3.5 cm) from the
3
8
A
C
D
30" (76.2 cm) models
A. 2" (5.1 cm) spacer the entire depth of the cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
" (3.5 cm) recess from front of cabinet
3
8
D. 11/16" (1.7 cm) side cleat*
*Cleats and spacers must be recessed 1
front of the cabinet
.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest
edition, and all local codes and ordinances.
A
B
D
TOP VIEW
" (3.5 cm) from the
3
8
3 of 12

Publicidad