3. Turn the cleaning pump ON & OFF by pressing ON/OFF switch (F) at the
front panel (L). A timer will shut off the cleaning pump automatically after 30
min. if the pump is left in the ON position. To minimize fluid consumption,
always turn the cleaning pump OFF after use by pressing the pump switch
(F) again.
Wet the sink, parts to be cleaned and any brushes prior to cleaning; this will
prevent grease and dirt from sticking to the surfaces.
The BIO-CIRCLE™ unit is supplied with an efficient multi-jet flow-through
brush, which is well suited for most cleaning applications. However, for best
results, when cleaning smaller or intricate parts, it is recommended to run the
cleaning solution through the flexible faucet (A) and use brushes that are well
adapted to the shape of the part being cleaned.
Always clean parts while holding them under the flow of liquid.
4. For optimum performance, always keep unit topped-up to the proper working
level of at least 100 liters/26.5 gal., do not fill above the MAX level. Do not
allow solution level to fall below 60 liters/16 gal. Observe fluid level lines
molded into the tank wall.
When the solution level falls below minimum, the float switch will cut power to
the cleaning pump and the heater coil. The air pump, however, will continue
running.
Check the fluid level every other week and top-up to operating level.
MAX 140 L / 37 gal.
100 L / 26.5 gal.
MIN 60 L / 16 gal.