Upon receipt of fi xture, thoroughly inspect for any freight damage. All
damage should be reported to the delivery carrier. Compare the catalog
description listed on the packing slip with the fi xture label on the inside
of the housing to be sure you have received the correct merchandise.
Note: Account for small parts and destroy packing material, as these
may be hazardous to children.
Turn OFF Power at circuit breaker box.
CAUTION: Do not rely on wall switch alone to turn off power.
OFL1 THK - Threaded Knuckle Mounting:
Required Tools: 1/4" hex socket driver
Remove locknut and thread knuckle into a 1/2" NPS hole in a
compatible mounting apparatus. Note: Seal arm thread using Tefl on
tape or silicone sealant. Reinstall locknut and tighten to secure. Refer to
wiring instructions for power connection on next page.
To adjust the tilt angle of the fi xture, loosen the 5/16" hex socket screw.
Rotate fi xture to the desired angle and re-tighten screw to 30ft-lbs.
4) 5/16" hex
socket screw
OFL1&2 YK - Yoke Mounting:
Required Tools: Hex socket driver and regular screwdriver.
To adjust the tilt angel of the fi xture, loosen but do not remove the 3/8"
hex bolts on both sides of the yoke. While holding weight of fi xture,
remove 10-32" set screw, adjust to desired angle and reinstall set screw
in appropriate matching hole. Re-tighten hex bolts to secure.
3/8" Hex bolt (2
plcs) use 9/16
socket driver
10-32" set screw
INSTALLATION INSTRUCTIONS
Mount fi xture to the desired bracketry using the hole pattern provided
on the yoke bracket (see template below) with a 5/8" bolt (if center hole
is used) or 1/2" bolts (if outer holes are used), lock washer, and nut (not
provided). Tighten to 30ft-lbs.
The Yoke Mounting option is provided with 16AWG power supply
cord. The power supply cord has 0.4 inch outside diameter (O.D.). A UL
LISTED water tight cord connector suitable for use on 0.4 inch diameter
size wet location fl exible cord shall be required in order to install onto an
outdoor junction box. See image below.
When installing onto an outdoor junction box and in order to reduce
risk of water entry, ensure that a Tefl on tape or silicone sealant is
applied on the threaded portion of the fi tting when being installed. It
is recommended that the water tight cord connector be installed so that
power supply cord exits towards the ground. If existing wiring does not
allow for installation of wires exiting towards the ground, the use of an
elbow suitable for wet location use is recommended so that cord can exit
towards the ground. See images below. Refer to wiring instructions on
next page for power connection.
page 3