affect that the generator operates on safe
way. If a strange noise is listened to or some
abnormal vibration, turn off the generator im-
mediately. Be sure to fix the problem before
giving the generator more use. Do not use the
equipment damaged. Periodically inspect all
the screws and bolts to check they are in place
and tight.
• Keep this equipment in a clean and dry place.
For the best maintenance of the engine and
any other problem, read the engine owner's
manual.
• After the engine has become cool, remove
the excessive gasoline and store it in a contain-
er, safe and approved for that purpose.
•After the first 20 hours of use of the genera-
tor drain and replace the oil of the engine,
after that the oil must be changed every 100
working hours.
• HEAT SHIELD: Inspect to ensure that all heat
shields and heat deflectors are intact and in
place. Removing of these parts could cause se-
rious damage to the unit.
• ENGINE: Carburetor icing during the winter
months, rare atmospheric conditions could
cause an icing condition in the carburetor. If
it happens, the engine may run rough, loose
power, and may stall. Call Product Service for
more information.
NOTE: Refer to the engine manufacturer's
manual for service and maintenance of the
engine.
SERVICE AND STORAGE
INFREQUENT SERVICE
If the unit is used infrequently, difficult start-
ing may result, to eliminate hard starting, run
the generator at least 30 minutes every 15
days. Also, if the unit will not be used for some
time, it is a good idea to drain the fuel from
the carburetor and gas tank.
LONG TERM STORAGE
When the generator set is not being operated
or is being stored more than one month, fol-
low these instructions:
• Replenish engine oil
to upper level.
• Drain gasoline from
fuel tank line and car-
buretor.
18
• Pour about one teaspoon of engine oil through
the spark plug hole, pull the recoil starter several
times and replace the plug. Then pull the starter
until you feel piston is on its compression stroke
and leave it in that position. This closes both the
intake and exhaust valves to prevent the inside
of cylinder from rusting.
• Cover the unit and store in a clean, dry place
that is well ventilated away from open flame
or sparks.
NOTE: We recommend always using a fuel sta-
bilizer. A fuel stabilizer will minimize the for-
mation of fuel gum deposits during storage.
The fuel stabilizer can be added to the gasoline
in the fuel tank, or into the gasoline in a stor-
age container.
TROUBLESHOOTING
NOISY GENERATOR
Worn or damaged bearings: Replace damaged
ball bearings and amke sure they are adequa-
tely adjusted.
HIGH VOLTAGE WITHOUT CHARGE
Excessive speed: Adjust speed.
Capacitor with excessive capacity: Verify and
replace.
LOW VOLTAGE WITHOUT CHARGE
Low speed: Adjust speed.
Damaged diodes: Replace diodes.
Damaged winding: Verify and replace.
Capacitor with low capacity: Verify and repla-
ce.
CORRECT VOLTAGE UNLOADED BUT LOW
WHEN LOADED
Low speed when loaded: Adjust speed.
Excessive load: Adjust load.
Damaged diodes: Verify and change.
ADEQUATE VOLTAGE UNLOADED BUT HIGH
WHEN LOADED
High speed when loaded: Adjust speed.
USTABLE VOLTAGE
Defective receptacles: Verify and change.
Irregular engine speed: Check engine carbura-
tion.