Troubleshooting - Magicvac P0608ED Instrucciones De Uso

Máquina profesional para envasado en vacío
Ocultar thumbs Ver también para P0608ED:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
MAGIC VAC
does not
®
work
MAGIC VAC
does not
®
perform the first seal on
the piece of cut roll.
MAGIC VAC
does not
®
completely vacuum-
pack the bags
MAGIC VAC
does not
®
correctly seal the bag
The MAGIC VAC
bag
®
doesn't maintain its
vacuum after sealing
MAGIC VAC
does not
®
seal containers.
MAGIC VAC
Executive
®
canisters or Universal
MAGIC VAC
Lids do
®
not maintain the seal

TROUBLESHOOTING

• Make sure the power cable on the MAGIC VAC
and in the electrical outlet. Check the electrical outlet by trying another device in
the same outlet.
• Make sure the power cable and/or plug is not defective. If so, do not use the
machine.
• Check that the piece of cut roll is correctly positioned as described in the
paragraph: "5 - Making bags from MAGIC VAC
integrity of the Sealing Gasket
• In order to correctly seal the bags, the open end must be entirely inside the Vacuum
Chamber (8). Check the correct position through the Lit WINDOW (3).
• Make sure the Sealing Bar(6), the Airtight Gasket (7) and Sealing Gasket (9) are
not dirty.
• The MAGIC VAC
bag may be punctured. To check, seal the bag with air inside,
®
place it under water and squeeze. If you see bubbles, there is a leak. Reseal or
use another bag.
• When you can't completely seal the bag, press the "sealing mode" button (2M)
and increase the sealing time.
• If the Sealing Bar (6) overheats and melts the bag, lift the Cover (5) and allow the
Sealing Bar (6) to cool for a few minutes.
• Check the position and integrity of the Sealing Gasket (9)
• If liquids escape during the vacuum-packing phase, remember that they must first
be refrigerated.
• Leaks along the seal can be caused by wrinkles, crumbs, grease or liquids. Open
the bag, clean the upper part of the inside of the bag and remove any residue from
the Sealing Bar (6) before resealing.
• Make sure the bag is not punctured and thus did not maintain the vacuum. Protect
any pointed edges of the contents in the bag using paper napkins.
• Using the Canister Tube (16), connect the canister lid (or the Lid Attachment if
necessary) and the ACCESSORY PORT (4) on the machine.
• Leave adequate space (at least 3 cm) between the contents and the top of the jar
or canister.
• Make sure that the rim of the jar or canister and universal lid are not damaged in
the sealing zone. Clean the rim and the lid with a damp cloth and reseal.
• Make sure the gasket on the canister lid or universal lid is placed in the correct
position and not damaged.
• Make sure the knob on the canister lid is set to "VACUUM" before vacuum-packing
and that it is set to "CLOSED" after it is complete.
• Check that the O-Ring under the knob on the canister lid or universal lid is correctly
positioned.
• Makes sure that the rim of the jar or canister and universal lid are not damaged in
the sealing zone. Clean the rim and the lid with a damp cloth and reseal.
• Make sure the gasket on the canister lid or universal lid is placed in the correct
position and not damaged.
• Make sure the connection tube is correctly connected to both the canister knob as
well as the ACCESSORY PORT (4) on the machine.
is fully inserted in the machine
®
rolls". Check the position and
®
25

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido