4. TECHNICAL SPECIFICATIONS
Parameter
System voltage
Maximum charge current
Self consumption
Battery voltage range
Max. PV open circuit voltage
Max. PV short circuit current
MPPT voltage range
Max. PV input power
Charge characteristic
Supported battery types
Maximum conversion efficiency
Maximum MPPT efficiency
LED indicators
Display
Battery temperature sensor
Alarm relay
Cooling
Protections
Operating temperature range
Storage temperature range
Communication
Connections (PV + Battery)
Dimensions (HxWxD)
Weight
Protection class
Standards
1)
Maximum output current tolerance is +/-5%. Automatic output current derating at Tambient > 45°C. Maximum output current is
programmable via Dashboard Mobile app.
2)
Selectable by setup button, display on solar charger or via Dashboard Mobile app
Please act according to your local rules and do not dispose of your old products
with your normal household waste. The correct disposal of your old product
will help prevent potential negative consequences for the environment and
human health.
OCS 150-60
1)
Vbatt + 2 up to 120Vdc
12V
24V
36V
48V
IUoUo, intelligent 3-stage, temp. compensated
2)
Flooded / Gel / AGM / LiFePo4 / Custom (user defined)
Charge mode, Battery state and Battery type
Battery and PV reverse polarity, output short circuit
Through Dashboard Mobile app (iOS and Android)
EMC: 2014/30/EU, Safety: EN62109-1, Functionality
12Vdc / 24Vdc / 36Vdc / 48Vdc
60A
0.54W
9.0 – 64.0Vdc
150Vdc
50A
800W
1600W
2400W
3200W
98%
99%
Yes (detachable for remote use)
Included
Yes (10A @ 230Vac or 30Vdc)
Natural convection (no fan)
and over temperature
-35°C ... +60°C
-40°C ... +80°C
Screw terminals (35mm
266x194x119mm
3.6kg
IP32 (mounted in upright position)
EN62509-1 and RoHS: 2011/65/EU
Note : the given specifications are subject to change without notice.
15
OCS 250-70
70A
250Vdc
40A
Vbatt + 2 up to 180Vdc
920W
1840W
2760W
3680W
2