Holding
Unit Down To Countertop
Jenn-Air
30" Unit
Jenn-Air
36" Unit
To hold the cooktop to the counter top, two hold down
brackets
have been provided.
Utilize the hold-down
brackets, one on the left and one on the right side of unit
to secure the unit to the counter top. Additional hold-down
brackets may be added to the front and/or rear. Contact
your dealer or authorized service agency.
Position the cooktop in the cutout opening.
Open cabinet doors and locate screw holes at right and
left side of unit bottom. Holes are half way between front
and rear of unit and approximately 1 1/4" from each side.
Thread the long hold-down screws into the hold-down
brackets.
Tighten hold-down screws to snug the unit top down
against the counter top. See figures 19 and 20. Do not
overtighten.
_,._
BRACKET
COUNTERTOP
BURNERBOX
HOLD-DOWN
To hold the cooktop to the counter top, slots for hold down
straps are located on all sides of the unit to accommodate
alternate mounting configurations. Two hold down straps
have been provided. Some counter top configurations
may not allow enough access to the hold-down screws
(and/or stabilization screws) on one or more sides of the
unit. Utilize hold-down
brackets
and when
possible
stabilization screws, one on the left and one on the right
side of unit to secure the unit to the counter top.
Additional, hold-down brackets and stabilization screws
may be added to the front and/or rear.
Order part #12001977 from dealer.
Position the cooktop in the cutout opening.
Open cabinet doors, and hook the hold-down brackets
into the slots provided in the burner box (see figure 21
and figure 22) and secure with short stabilization screw(s)
provided. A 1/4" socket wrench or nut driver may be
required to tighten short screws. Do not overtighten.
Thread the long hold-down screws into the hold-down
brackets.
Tighten hold-down screws to snug the unit top down
against the counter top. See figure 22. Do not
overtighten.
__/
FIGURE21
RGURE20
HOLD-DOWN SCREW
How To Remove
Cooktop
For Servicing
Follow this procedure to remove the cooktop for servicing:
1. Shut off gas supply to the cooktop.
2. Disconnect electrical supply to appliance, if
equipped.
3. Disconnect gas supply tubing to appliance.
4. Remove tie down brackets. (See figure 19).
5. Reverse the procedure to reinstall. If gas line has
been disconnected, check for gas leaks after
reconnection.
NOTE: A qualified servicer should disconnect and
reconnect the gas supply.
The servicer MUST follow installation instructions
provided with the gas appliance connector and the
warning label attached to the connector.
COUNTERTOP
STABILIZATION
SCREW
FIGURE22
12
Service-Parts Information
When your cooktop requires service or replacement parts,
contact your dealer or authorized service agency. Please
give the complete model and serial numbers of the unit
located on the cooktop model number plate.