BATTERY PROTECTION
LEVEL ADJUSTMENT
The battery protection level defines the minimum voltage under which power to the product is
interrupted.
To set the battery protection level, proceed as follows:
- with the product off, press and hold the "Silent Night" and "Smart" buttons for 3 seconds. This makes it possible to display/
set the battery protection level.
- Each time the intensity button is pressed, another LED lights up until the maximum level is reached (5). Once at level 5,
pressing it again starts over from level 1.
- To save the change, wait until the display stops flashing and turns off. Once restarted, the appliance will use the newly set
values.
RECOMMENDATIONS FOR USE
- If possible, turn on the appliance about 6 hours before adding products.
- Frequent opening of the appliance leads to greater power consumption.
- Adequate ventilation of the compressor and condenser significantly reduces power consumption.
- Never block the product's ventilation system.
- The electrical system must be in excellent conditions. Check the batteries and their charge level regularly. Always use a
starter battery separate from the motor.
- The compressor can operate at an inclination of up to 30°. Greater angles may cause permanent damage to the compressor.