Descargar Imprimir esta página

Craftsman 580.752860 Manual De Instrucciones página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

Check and Clean Water Inlet Screen
Remove water inlet coupling (A). Then remove water inlet
screen (B) from the unit's water inlet (C) using a needle nose
pliers. Water inlet is located at bottom front of unit. Examine
water inlet screen. If the screen is dirty, clean with a small
brush and water. If the screen is damaged, replace it.
CheckSpray Gun
Examinethe hose connection to the spray gun and make sure
it is secure. Test the trigger (D) by pressing the trigger lock
button (E) and making sure the trigger "springs back" into
place when you release it. You should not be able to press
the trigger without pressing the trigger lock button. Replace
spray gun immediately if it fails any of these tests.
Check High Pressure Hose
The high pressure hose can develop leaks from wear,
kinking, or abuse, inspect the hose each time before using it.
Checkfor cuts, leaks, abrasions or bulging of cover, damage
or movement of couplings. If any of these conditions exist,
replace the hose immediately.
,_. WARNING The high pressure stream of water that this
_
quipment produces could cut through skin and
its underlying tissues, resulting in serious injury
and possible amputation.
• NEVERrepair high pressure hose. Replace it.
• Replacement hose rating MUST equal or exceed
maximum pressure rating of unit.
Check Steam Hose
The steam hose can develop leaks from wear, kinking, or
abuse, inspect the hose each time before using it. Check for
cuts, leaks and abrasions, if any of these conditions exist,
please call 1-800-222-3136 for assistance.
Check Detergentand Water TankSiphoning
Tubes
Examine the tubes and clean if clogged. Examine the tubes
for leaks or tears and replaceif damaged.
CheckSteam Gun
Test the trigger by pressing trigger release(F), then squeeze
trigger (6). Make sure the trigger "springs back" into place
when you releaseit. Press trigger lock (H). You should
not be able to squeezethe trigger. Replacespray gun
immediately if it fails any of these tests.
//
,3 ........................
_'_"4-_
-,
!_
_ .............
//
Clean Steam GunTip
1. Press the master ON/OFFswitch to the OFF(0) center
position. Removepower cord plug from electrical outlet.
2. Allow at least 10 minutes for unit to cool.
.
Slide brush attachment (J) off end of gun (K). insert end
of wire tip cleaner (IVl)into small opening repeatedly to
remove any clog or sediment buildup. The wire tip cleaner
is stored at the lower back left of the unit.