Descargar Imprimir esta página

ims PRO IMS 220E FV CEL Manual Del Usuario página 26

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Output to welding
HMI
Available in TIG
PULSE only
TROUBLESHOOTING
This device integrates a default management system. In the event of a default, error messages may be displayed.
Error code
«UE1»
«UE2»
«HE1»
26
2s
2s
Back to the Setup
2s
menu
Back to the Setup
2s
menu
Back to the Setup
2s
menu
Back to the Setup
2s
menu
Back to the Setup
2s
menu
Meaning
Thermal protection
Mains overvoltage fault
Mains undervoltage fault
Fan fault
Power relay control fault
IMS 220E FV CEL
Value
current
...
Choice
current
...
Value
current
...
Value
current
...
Value
current
...
Value
current
...
CAUSES
"Exceeding the duty cycle
Ambient temperature above 40°C
Blocked air inlets
"
Mains voltage outside maximum tolerance
Mains voltage outside minimum tolerance
The fan is not running at the right speed.
The power relay could not be closed
...
...
...
...
...
...
1s
1s
1s
SOLUTIONS
"Wait for the indicator to turn off before resuming
welding operations.
Observe the operating factor and ensure good
ventilation"
Have the sensors connection checked by a qualified
person.
Have your electrical installation checked by a qua-
lified person. The mains voltage must be between
95Vrms and 265Vrms.
Check for foreign bodies that could slow down the
fan, check the correct wiring, replace the fan
Have the wiring of the relay control system checked
by qualified personnel
EN
I. Start
10% ... 200%
Up Slope
0.0s ... 10.0s
Frequency
0,5 Hz ... 20.0 Hz
Pourcentage (I cold)
20% ... 80%
Duty cycle
20% ... 80%
Down Slope
Validation +
Output to welding HMI
0.0s ... 10.0s
Reset all process parameters
(except memoirs)
+
Output to welding HMI

Publicidad

loading