The charger must always be switched off when connecting the Program Shooter.
When switched on, the display turns on and provides information on temporary
screens presenting the current charger settings:
FW 0.23
Firmware and charger model.
Q2 12V
Current charger set up.
12V 5A
E.g.: Charger 12V 5A for Wet lead batteries
WET Flo
with Floating end-of-charge.
Charger
Title of the charger settings menu.
Settings
The main operating mode setting.
Mode
Press the knob to enter the menu and turn it to choose between
Menu
Battery Charger and Power Supply.
Press to confirm.
Tech
Menu
Sel Tech
WETD
Set Batt
Voltage
Voltage
24V
Set Batt
Current
Current
15A
Select
Equ Flo
Floating
Charge
Saving
Menu
Save
Data?YES
After choosing the option to save the settings, wait until the message MEMORISED
DATA appears, then remove the Program Shooter.
FUNCTIONING - COMMANDS AND DISPLAYS
Description of the Battery Charger mode menu
Battery technology setting.
Press to enter menu.
Turn to select charge curve.
E.g.: Wet Deep for lead-acid battery with depth charge.
Press to confirm.
The battery voltage setting.
Press to enter menu.
Turn to select the voltage.
E.g.: 24V
Press to confirm.
The charging current setting.
Press to enter menu.
Turn to select the charging current.
E.g.: 15A
Press to confirm.
The end of charge setting.
Press to enter menu.
Turn to select end of charge.
E.g.: Floating
Press to confirm.
Saving the settings.
Press to enter menu.
Turn to select whether to save
the settings YES / NO.
Press to confirm.
TURN
PRESS
6.