INSTALLATION SPACING FOR CABINET INSTALLA TION
• For cabinet installation
with a door, minimum
ventilation
openings
in the top of the cabinet are required.
*Required
spacing
**For side or bottom
venting,
2 inches (5.1 cm) spacing is allowed.
7"_(17.8 cm)
7,,*(17.8 cm)
,_ (22.9
cff 0
!
5"*_
30"
1 "*_
1"
27"
(12.7 cm)(76.1 cm) (2.5 cm) (2.5cm)(68.6 cm)(2.5 cm)
CLOSET VENTILATION REQUIREMENTS
Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup
in the closet. One
upper vent opening
with a minimum
opening
of 48 sq. in. (310 cm 2) must be installed no lower than 6 feet above the
floor. One lower vent opening with a minimum
opening
of 24 sq. in. (155 cm 2) must be installed no more than one
foot above the floor. One example
shown uses vent grilles in the door.
RECOMMENDED
INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION,
WITH STACKED WASHER
AND DRYER
• The dimensions
shown are for tile recommended
spacing.
*Required
spacing
**For side or bottom
venting,
2 inches (5.1 cm) spacing is allowed.
48 in.2 *
(310 crn 2)
3_ (7.6 crn)
Z
7.6 cm_
24 in? *
(I 55 crn2)
_r_
1"* (2.5 crn}
5w4"**
(14 crn)
6"* (15.3 crn)
68.6 cm
(2.5 cm)