3.3.1.3.
Charging by a car
Connect one end of the car charger to the cigarette lighter port, connect the other end to the 7909 input
port (14), the charging indicators (3) and (4) will turn green.
Failure to comply with the following recommendations may damage the battery.
1. Charge the battery before storage and charge it fully at least 6 months. Store the unit in a cool
and dry place.
2. If the main power supply shuts down automatically due to lower battery capacity, recharge the
battery within 3 months. Otherwise, the battery capacity will not be restored.
Low temperatures (below zero) can affect the capacity of the power station battery. If kept in sub-zero
conditions, the battery may be discharged. Never charge the unit in sub-zero conditions as this will
damage the battery and its capacity may not be recovered.
3.3.2.
Description of alert information
3.3.2.1.
Overload
When the output power in use is higher than the specified output power that can be applied to the model,
the "OVERLOAD" indicator will light up red. It is necessary to reduce the power of the electrical
equipment. If the AC output is turned off during this time, press the AC ON/OFF button again and restart
the unit.
3.3.2.2.
High temperature
When the internal temperature is higher than 35 degrees Celsius or the output power is higher than
700 W, the cooling fan starts to operate. When the internal temperature is higher than 85 degrees Celsius,
the temperature alarm sounds. The AC and DC outputs will be switched off and the "OVERHEAT" indicator
will turn red, causing the operation to stop immediately. To restart the unit, wait until the temperature
drops below 35 degrees Celsius.