Haverland ANUBIS Manual De Uso página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
3. OPERATION
B
3
ON/OFF: Press the switch button on the right side to turn the appliance.
LIGHT: The red light between the two knobs lights up when the device is
heating.
MODE SELECTION KNOB: Please note the temperature can only be adjusted
under COMFORT MODE.
COMFORT MODE: Under Comfort Mode, you can set your desired
temperature from 10°C to 35°C with the Temperature Setting Knob.
There are 9 graduations on the Temperature Setting Knob from 1 to 9
which define the temperature from 10°C to 35°C ( at "1", the temperature
will be maintained at around 10°C while at "9", the temperature will be
maintained at around 35°C ).
The product has a built-in thermostat, when ambient temperature is
below the set temperature, the heater will operate and the red indicator
light will illuminate. When the ambient temperature is above the set
Temperature, the heater will stop operating temporarily and the red
indicator light will be switched off.
• ECO MODE: Under ECO Mode, you can set your desired temperature
from 7°C to 32°C with the Temperature Setting Knob.
There are 9 graduations on the Temperature Setting Knob from 1 to 9
which define the temperature from 7°C to 32°C ( at "1", the temperature
will be maintained at around 7°C while at "9", the temperature will be
maintained at around 32°C ).
The product has a built-in thermostat, when ambient temperature is
below the set temperature, the heater will operate and the red indicator
light will illuminate. When the ambient temperature is above the set
Temperature, the heater will stop operating temporarily and the red
indicator light will be switched off
ANTI-FREEZE: Under this mode, the heater will maintain a steady
temperature of 7°C. The product has a built-in thermostat, when
ambient temperature is below 7°C, the heater will operate and the red
indicator light will illuminate. When the ambient temperature is above
7°C., the heater will stop operating temporarily and the red indicator
light will be switched off. This is to prevent frost formation in the room
at lowest energy consumption.
STAND-BY: When the room temperature has reached the desired
temperature and you want to stop the heater temporarily and choose a
different operation later, you can switch the heater to the STANDY-BY
mode during which the heater will stop working.
ANUBIS
28
3. OPERATION
EN
EN
ANUBIS
29

Publicidad

Tabla de contenido
loading

Tabla de contenido