5. PROGRAMMING FUNCTION WITH
R- CONTROL
LIWIN RADIO
UP
STOP
DOWN
SELC
PROG
5.1.DIP-SWITCH 1: STORAGE OF THE TRANSMITTERS
To store a transmitter TX1 on a blank actuator proceed as follows:
To store a transmitter on a blank actuator proceed as follows:
A Prepare the electrical connection to the main voltage 230 VAC, but do not connect the actuator
B Set the transmitter dip-switch no.1 into ON position (all the other dip-switches must be in OFF position)
C R6 control only: press the key SELC of the transmitter repeatedly, until displayed by the leds the selected
channel
D Connect the actuator to the 230 VAC voltage
E Within 5 sec press and hold (for about 3/4 sec) the key PROG of the transmitter TX1
F Release the key PROG
G Set the transmitter dip-switch no.1into OFF position
H Wait 10 sec
I Pressing the keys UP or DOWN, the actuator moves in opening/closing direction
DIP
Function
1
Storage of the transmitters
Deletion of all the stored transmitters
3
2-4
Not used
UP
STOP
DOWN
SELG
SELC
DIP-SWITCHES
PROG
MCU RADIO
SELG
DIP-SWITCHES