Descargar Imprimir esta página

Casanoov BUNKER B500 Manual página 27

Ocultar thumbs Ver también para BUNKER B500:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90
EN
Setting of the control board
1.To set the soft start time :
When the digital display shows P0, the actuator is in soft start time setting mode.
The option is adjustable from 0 to 6s (default 2s)
00: Soft start disabled.
2.To set the obstacle sensitivity level:
2a-- When the digital display shows P1, the actuator is in Motor 1 sensitivity setting mode at low
operating speed. Options range from level 0 to 20 (default 8).
The lower the value, the more sensitive the motor will be to obstacles.
2b-- When the digital display shows P2, the actuator is in high speed Motor 1 sensitivity setting mode.
Options range from level 0 to 20 (default 12).
The lower the value, the more sensitive the motor will be to obstacles.
2c-- When the digital display shows P3, the actuator is in low speed Motor 2 sensitivity setting mode.
Options range from level 0 to 20 (default 8).
The lower the value, the more sensitive the motor will be to obstacles.
2d-- When the digital display shows P4, the actuator is in high speed Motor 2 sensitivity setting mode.
Options range from level 0 to 20 (default 12).
The lower the value, the more sensitive the motor will be to obstacles.
3.To set the duration of high-speed operation :
When the digital display shows P5, the actuator is in high speed run time setting mode.
Options range from 0 to 33s (default 12s)
00: High speed disabled
4.To set the automatic close time for external devices:
When the digital display shows P6, the actuator is in the Auto Close Time setting mode for external
devices.
Options range from 0 to 99s (default 10s)
00: The gate will not close automatically.
5.To set the gate leaf interval time :
5a. When the digital display shows P7, the operator is in open interval time setting mode. Options range
from 0 to 10s. (default 0s)
00: Both doors open simultaneously.
00 - 10: Motor 1 starts to open 0-10 seconds before motor 2 starts to open.
27

Publicidad

loading

Este manual también es adecuado para:

Sti-000122Jj-pkm-b01