Descargar Imprimir esta página

Ariston GA3 124 IX A1 Manual De Instrucciones página 6

Ocultar thumbs Ver también para GA3 124 IX A1:

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING : Modification of the appliance and
its method of installation are essential in order to
use the appliance safely and correctly in all the
additional countries
Use pressure regulators suitable for the gas
pressure indicated in the instructions.
The room must be equipped with an air
extraction system that expels any combustion
fumes.
The room must also allow proper air circulation,
as air is needed for combustion to occur normally.
The flow of air must not be less than 2 m³/h per
kW of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an inner
cross section of at least 100 cm²; the opening must
not be susceptible to blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as described above.
However, these rooms must not be communal
rooms, bedrooms or rooms that may present a fire
hazard.
Liquid petroleum gas sinks to the floor as it
is heavier than air. Therefore, rooms containing
LPG cylinders must also be equipped with vents
to allow gas to escape in the event of a leak.
This means LPG cylinders, whether partially or
completely full, must not be installed or stored
in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the
cylinder being used in the room, positioned so
that it is not subject to heat produced by external
sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above
50°C.
Should you find it difficult to turn the knobs for the burner, please
contact the After-sales Service, who can replace of the burner tap if
found to be faulty.
The openings use for the ventilation and dispersion of heat must never
be covered.
Carry out all cabinet cutting works before
fitting the appliance in the furniture and remove
all wood chips and sawdust.
Do not remove the appliance from its polystyrene
foam base until the time of installation.
After installation, the bottom of the appliance
must no longer be accessible - risk of burn.
Connection with rigid pipe (copper or steel):
If the gas pressure is different from the
recommended pressure, a suitable pressure
regulator must be fitted to the inlet pipe in
accordance with the current national regulations.
Use an appropriate cabinet to ensure that the
appliance operates properly: To install the oven
under the counter (see diagram) or in a kitchen
unit, the cabinet must have the dimensions as the
picture.
To ensure adequate ventilation, the back panel
of the cabinet must be removed. It is advisable
to install the oven so that it rests on two strips
of wood, or on a completely flat surface with an
opening of at least 45 x 560 mm as the picture.
Do not install the appliance behind a decorative
door - risk of fire.
If the appliance is installed under the worktop,
do not obstruct the minimum gap between the
worktop and the upper edge of the oven - risk of
burns.
GAS CONNECTION
WARNING : Prior to installation, ensure that the
local distribution conditions (type of gas and gas
pressure) and the configuration of the appliance
are compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Table 1
("Burner and nozzle specifications").
WARNING : The configuration conditions of
this appliance are stated on the label (or data
plate).
WARNING : This appliance is not connected
to a combustion products evacuation device. It
must be installed and connected in accordance
with current installation regulations. Particular
attention must be paid to the relevant
requirements regarding ventilation.
If the appliance is connected to liquid gas,
the regulation screw must be fastned as tightly as
possible.
IMPORTANT : When the gas cylinder or gas
container is installed, it must be properly settled
(vertical orientation).
WARNING : This operation must be perfomed
by a qualified technician
Use only flexible or rigid metal hose for gas
connection.
Connection with a rigid pipe (copper or steel)
Connection to the gas system must be carried
out in such a way as not to place any strain of
any kind on the appliance. There is an adjustable
L-shaped pipe fitting on the appliance supply
ramp and this is fitted with a seal in order to
prevent leaks. The seal must always be replaced
after rotating the pipe fitting (the seal is provided
with the appliance). The gas supply pipe fitting is
a threaded 1/2 gas cylindrical male attachment.
Connecting a flexible jointless stainless steel
pipe to a threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas
cylindrical male attachment. These pipes must
be installed so that they are never longer than
2000 mm when fully extended. Once connection
has been made, make sure that the flexible metal
pipe does not touch any moving parts and is not
compressed. Only use pipes and seals that comply
with current national regulations.
IMPORTANT : If a staineless steel hose is used,
it must be installed so as not touch any moving

Publicidad

loading

Este manual también es adecuado para:

Ga3 124 c ix a