INSTRUCTIONS FOR THE INSTALLER
GAS CONNECTION
Before installing, ensure that the local distribution conditions (gas nature and pressure) and the oven regulation are compatible.
To do this, verify the data of the product label applied on the oven and this booklet.
The gas connection must comply with Standards. The oven must be connected to the gas plant using stiff metal tubes or stainless-steel flexible
tubes in the wall, with a maximum extension of 2 m.
When using flexible metal tubes, ensure that they do not come into contact with moving parts or are crushed.
Carry out the connection so as not to cause any kind of stress on the apparatus.
The gas input connection is threaded "G1/2".
For ISO R7 connections, it is not necessary to interpose the gasket.
For ISO R228 connections, it is necessary to interpose the head washer provided.
After the connecting operations, verify the connections sealing with a soapy solution.
Electrical connection
Ensure that the voltage corresponds to that indicated in the plaque located on the oven door frame.
The cables for the connection to the mains must be protected from direct contact with the oven's metal casing.
THE PLAQUE MUST NEVER BE REMOVED
Warning: the earth connection must be compliant with law.
If using a fixed direct connection to the electrical network, it is necessary to provide a proper device with ensures the
disconnection from the mains with a distance of contact opening which allows complete disconnection in conditions of
overvoltage category III, in accordance with the rules of installation. Avoid using reductions or adaptors as they may cause
overheating or burning.
After installation, carry out a brief oven check, following the instructions reported further down. In case the appliance does not function,
disconnect it from the mains and contact the after-sales assistance centre nearest to you.
DO NOT ATTEMPT TO REPAIR THE APPLIANCE
The oven is provided with a cable without a plug. The plug to be used must be the standardised, being aware that:
•
Yellow-green: earth
•
Blue: neutral
•
Brown: phase
WARNING!
The manufactures declines any liability for damage suffered by persons and things, caused by the non-compliance of the above
prescriptions or deriving from the tampering of even a single part of the appliance and use of non-original spare parts.
Technical specifications
TYPE OF BURNER
TYPE OF GAS
OVEN
LIQUID GAS
GRILL
LIQUID GAS
OVEN
NATURAL GAS
GRILL
NATURAL GAS
.
.
PRESSURE
NOMINAL THERMAL
(mbar)
POWER (kW)
G30/31
28..30/37
3.1
G30/31
28..30/37
2.4
G20
20
3.1
G20
20
2.4
EN
GAS
INJECTOR MARKING
CONSUMPTION
(1/100) mm
189 g/h
79
124 g/h
60
296 l/h
125
229 l/h
108