Page 6
ENGLISH
Section 2. Installation
2.1
Installation Location
The pump should be installed on a firm, level base
or pad. When using factory supplied base ensure
installation is level and vibration-free. Pump must
be installed below the water line.
Keep pump below water level
Make sure surface
is leveled and firm
Although the pump is designed for outdoor use it
is recommended that the installation consider the
following:
•
Drainage – away from pump.
•
Run off from eaves and sprinklers.
•
Ventilation of pump motor.
•
Access for future servicing and winterizing.
•
Protection from the elements.
•
Sun exposure.
Position the filter a minimum of 5 ft (1.5 m) from the
pool or separated by a permanent barrier. Position
the filter and all components of the filtration system
so they can NOT be used as a means of access
to the pool by young children. In Canada, the
minimum distance maintained from the edge of the
pool and/or spa as noted above must be 3 meters
(10 feet), as required by the Canadian Electrical
Code (CEC, CSA C22.1). Swimming pool pumps
located within 3 meters (10 feet) of the pool walls
must be specifically approved for this purpose.
To Reduce the Risk of Fire, install pool equipment in
an area where leaves or other debris will not collect
on or around the equipment. Keep surrounding
area clear of all debris such as paper, leaves, pine-
needles and other combustible materials.
In order to avoid premature failure or damage to
the pump motor, protect the pump from direct water
exposure from sprinklers, water runoff from rooftops
and drainage, etc. Failure to comply may cause
pump failure, and may also void warranty.
5 ft
(1.5 m)
WARNING
CAUTION
Polaris
2.2
General Connections
2.2.1 Solvent Weld Connections
Rigid or flexible PVC pipe can be used. Pipe ends
should be clean and free of any flash cause by the
cutting operation. Be sure that the proper adhesive
is used on the type of pipe specified.
NOTE:
A primer will assure that adhesive joints are
superior. Suregard P-3000 has a purple tracer
to qualify in areas where codes specify a
primer must be used.
We recommend that you consider climatic conditions
when applying adhesives. Certain atmospheric
situations, such as high moisture content, make
adhesive action of certain glues less effective. Check
the manufacturer's instructions.
2.2.2 Threaded Connections
Use only Teflon tape or equivalent on threaded
plumbing connections. Other pipe compounds may
damage threads. We do not recommend the use of
silicone or petroleum based compounds.
DO NOT OVERTIGHTEN – HAND TIGHTEN PLUS
½ TURN IS SUFFICIENT.
2.3
Pump Plumbing
Suction pipe should be as large or larger than the
discharge pipe. Avoid using a suction pipe that is
smaller than the pump connection.
1.
Keep the piping as straight and short as
possible, and of suitable size.
2.
Avoid connecting an elbow directly into the
pump inlet (use a length of straight pipe to
allow a proper entry for the water).
3.
Support the pipe independently so that it
places no strain on the pump.
4.
It is recommended that valves are installed on
the suction and outlet lines to prevent water
from draining when servicing the pump. Never
run the pump with valves closed.
2.4
Electrical Data
•
Refer to information on motor nameplate for
electrical service data.
Failure to provide data plate voltage (+/- 10%) during
operation will cause the motor to overheat and may
void the warranty.
•
All motors should have fused disconnect switch
or circuit breaker.
Be sure wire size is sufficient for pump HP and
•
distance from power source.
Pump | Owner's Manual
™
®
Forza
CAUTION
CAUTION