3.3 Emptying the water tank
There are two ways to empty the water tank: manual emptying or continuous emptying.
3.3.1 Manual emptying
1.
Press the power button to turn off the product.
2.
Remove the water tank from the product.
3.
Discard the water.
•
If necessary, clean the inside and outside of the water tank.
4.
Place the water tank back into the product.
5.
Press the power button to turn on the product.
6.
If the indicator light indicating that the water tank is full is still on, check that you have
correctly reinserted the water tank and there are no blockages.
3.3.2 Continuous emptying
1.
Place the product on a horizontal and stable surface.
2.
Turn off the product.
3.
Secure the drain hose in the designated hole and check that there are no obstructions.
4.
Place the end of the drain hose in a well or bucket. Check that the water can flow through it
properly.
5.
Do not immerse the end of the drain hose in water, this may cause air to become trapped
in the hose.
Make sure the drain hose is pointing toward the ground.
•
The drain hose should be tilted downward more than 20°.
•
Make sure the hose is not bent or kinked.
•
3.4 Defrost function
•
When the ambient temperature is above 5°C and below 10°C, the compressor stops after
30 minutes of continuous operation and will defrost for 10 minutes. During defrosting, the
power indicator will flash and the fan will operate on "high" position.
•
If the ambient temperature is above 11°C and below 18°C, the compressor stops after 45
minutes of continuous operation and will defrost for 10 minutes. During defrosting, the
power indicator will flash and the fan will operate on position 'high'.
•
If the ambient temperature is above 18°C, the compressor does not need to defrost.
3.5 Turning on the drying function
1.
Turn on the product by pressing the power button.
2.
Press the mode button.
3.
Wait until the top light above the mode button turns on.
4.
The drying function is now activated
26
4. TROUBLESHOOTING
Problem
Cause
No power.
The water tank is full.
The product is not working.
Ambient temperature is
below 5°C or above 35°C.
The air grille is clogged.
The product is not working
properly.
The air inlet or outlet is
blocked.
No air enters the product.
The air grille is clogged.
The product is not on a
The product makes a loud
horizontal and level surface.
noise when it is on.
The air grille is clogged.
Problem with humidity
E2 is shown on the display.
sensor
The ambient humidity is
LO is shown on the display.
below 20%.
The ambient humidity is
HI is shown on the display.
above 90%.
The ambient temperature is
CL is shown on the display.
below 5%.
CH is shown on the
The ambient temperature is
display.
above 35°C.
5. MAINTENANCE AND CLEANING
5.1 Cleaning
Clean the product with a damp, clean cloth and dry it thoroughly. Do not use abrasive or
aggressive cleaning agents.
English
Solution
Plug into a working outlet.
Empty the water tank and
place it back in the product.
The product is protected
against overheating. The
product does not operate
outside the specified
temperature range.
Clean the air grille as indicated
in the manual.
Remove the blockage.
Wash the air grille.
Place the product on a proper
surface.
Wash the air grille.
Replace the sensor.
This is an indication. The
product turns off automatically.
27