Descargar Imprimir esta página

Tennant IPC PW-H61 Manual De Instrucciones página 8

Ocultar thumbs Ver también para IPC PW-H61:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
DESCRIPTION OF SYMBOLS
SWITCHING OF THE PUMP
MOTOR.
DETERGENT
DELIVERY SELECTOR.
LIGHTING THE BURNER /
TEMPERATURE
MENT.
MAINS POWER.
FUEL LEVEL
PROGRAMMED MAINTENAN-
CE INTERVAL EXPIRED.
FAULT INDICATOR
MOTOR THERMAL
PROTECTION INDICATOR.
6
A - On/off switch.
B - Lighting the Burner / Temperature adjustment.
C - Power indicator light.
D - Diesel level indicator light.
E - Maintenance indicator light.
F - Fault indicator light.
G - Motor Thermal indicator light.
SOLUTION
Start the cleaner by turning the selector switch "A"
to pos. "I".
In this position, you can control the water temper-
ADJUST-
ature from minimum to maximum, by using regulator
"B".
Warning
The high pressure water jet generates a reaction
force in the lance. Keep a firm grip on the lance han-
dle.
By positioning switch "A" on pos. II "Chem 50%", it
activates the supply of the detergent solution at 50%
of the full capacity.
The water temperature can be set using regulator
"B" at a recommended degree of 60°C.
By positioning switch "A" on pos. III "Chem 100%",
it activates the supply of the detergent solution at
100% of the full capacity.
The water temperature can be set using regulator
"B" at a recommended degree of 60°C.
SIGNALS AND FAULTS DISPLAYED
Indicator light C): Power is on when the indicator
light is on steady (switch "A" in pos. I); when the indi-
cator light is flashing, the high pressure washer is in
"TSI" status.
Led Lights pressure washer running, led in scoring
when waiting, led flashing in "TSI" status.
Indicator light D): Fuel level; the light on indicates
low fuel level.
Indicator light E): 200h programmed maintenance
interval expired. The light will go off following main-
tenance by the authorised service centre.
Indicator light F): Fault indicator:
- 2 flashes, Micro-leak alarm.
- 3 flashes, no water alarm.
- 5 flashes, Auto-reset "TSI" status
- 6 flashes, Temperature NTC probe failure alarm.
- 7 flashes, Anti-flood alarm (1h operation).
Indicator light G): Motor thermal protector activated.
EN - english
CONTROL PANEL
USING THE CLEANER

Publicidad

loading

Este manual también es adecuado para:

Ipc pw-h101