View the version by pressing key "OK".
Press key "ESC" to go back to the main submenu.
By pressing key "ESC" once more, you go back to
the preset temperature.
Indicator lights:
Indicator light C): Power is on when the indicator
light is on steady (switch "A" in pos. I); when the in-
dicator light is flashing, the high pressure washer is
in "TSI" status.
Led Lights pressure washer running, led in scoring
when waiting, led flashing in "TSI" status.
Indicator light D): Fuel level; the light on and rela-
ted message on the Display, indicates low fuel level.
Indicator light E): Faults signals: Identified faults
are reported on the display. See possible faults.
Indicator light F): Descaler level; the light on and
related message on the Display, indicates low level.
Indicator light G): Detergent solution level; the li-
ght on and related message on the Display, indicates
low level.
Indicator light H): Temperature Readiness; if this
light turns-on on the display, it means that the preset
temperature has been achieved.
If the preset temperature is not achieved within 4
minutes of normal hot water functioning, the light fla-
shes rapidly. Regulate the regulating valve slightly to
reduce the water flow. This will allow the attainable of
the prest temperature.
If the preset temperature lowers while using the hot
water function, the light flashes slowly until it reaches
the desired temperature.
HIGH PRESSURE WASHER SHUTDOWN -
POSSIBLE FAULTS
1) High pressure washer not used for more than 20
min., high pressure washer in total stop mode (TSI).
This is signalled by indicator light C) and E) flashing
and related message on the Display.
2) Low fuel level: the burner shuts down and not hot
water is delivered.
The fault is signalled by indicator light D) on steady
and related message on the Display.
3) 250h programmed maintenance interval expired.
The light will go off following maintenance by the au-
thorised service centre.
The fault is signalled by indicator light E) on steady
and related message on the Display.
4) Micro-leaks detected or water nozzle clogged: the
high pressure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
5) No water: After 90 sec. of operation with no water
detected, the high pressure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
6) Motor thermal protector activated: the high pres-
sure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
7) High Temperature Fault: The burner shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
8) Flame-on Fault: The pressure washer shuts down
The fault is signalled by indicator light E) flashing
and related message on the Display.
9) Flame-off Fault: The burner shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
N.B. To reset the fault signals, turn main switch
"A" to pos."0" and then back to pos. "I".
For further assistance, contact the technical ser-
vice centre.