IMPORTANT SAFETY NOTICE
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician
determine that the ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded
branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire
with ground. Please also refer to Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes.
Check with local requirements, purchase and install appropriate connector if necessary.
4