1. Motor Protective Filter (in the Dust Container)
Cleaning the Filter Element
Important:
Always empty the dust container fi rst before remo-
ving the fi lter element.
Press the button to release the dust container
and then remove it (see illustration 1).
Remove the contents of the dust container. In
order to do this, press the button on the dust
container (see illustration 2). Unlock the fi lter
element by pressing briefl y in a clockwise
direction (see illustration). In the second step
the fi lter element can be removed by pulling
downwards
Clean the motor protection fi lter by tapping
and gently brushing out.
Now replace the components.
Then close the fl ap of the dust container again.
Every third time the dust container is emptied,
or in the case of severe soiling, clean the fi lter
by allowing water to fl ow through the fi lter fabric
against the direction in which the vacuum cleaner
blows. The dust container should only be reinser-
ted when it is completely dry!
Now place this back in position once it has com-
pletely dried!
Caution:
Never wash the fi lter in the washing machine,
and please do not use a hairdryer to dry it.
2. Inlet fi lter
The inlet fi lter is located below the dust container
compartment. Press the button to release the dust
container and then remove it. Turn the fi lter in an
anticlockwise direction in order to remove it. Clean
the inlet fi lter approximately every tenth time the
dust container is emptied, or more frequently
if necessary. Please ensure that the fi lter is
always clean, as otherwise air circulation
cannot be guaranteed. If necessary, the fi lter
can also be washed in warm water without any
additives. Place it back into place only once it is
completely dry!