Descargar Imprimir esta página

Optimus M02-700RTH Manual De Instalación Y Funcionamiento página 10

Receptor ip con una salida de musica y una salida de avisos

Publicidad

Idiomas disponibles

Idiomas disponibles

6. COMMISSIONING OF THE DEVICE
To commission the MO2-700ETH we must send configurations to it via an Ethernet connection. Accomplishing this requires a PC
equipped with a network card and connected to the MO2-700ETH through a switch or directly using a network cable. The PC must
have the configuration software installed.
1. Make the connections between the devices.
2. Turn on the power supply to the devices.
3. Use the Call Point or Call Point Configurator software to configure the parameters of the MO2-700ETH and send the settings to
the device
ATTENTION. In order to be able to send configurations to the device, it is necessary that the device and the PC are
within the same IP address range. It is also necessary that the network addresses of the device and those set from the
configuration software match.
By default, the device's network configurations are as follows:
IP ADDRESS:
NETMASK:
GATETEWAY: 0.0.0.0 (without Gateway)
If you wish to assign a different network address to the unit than the default one, follow the next section 6.1.
Configuration of the MO2-700ETH network addresses.
6.1. Configuration of the MO2-700ETH network addresses
To change the default network settings of the MO2-700ETH do the following:
1. From the PC, open a browser, enter the IP address of the unit and press ENTER.
By default, the IP address is 10.1.1.1: The IP address range of the device and
those of the PC must match. If this is not the case, you must first change the
network settings of the PC to bring it within the range of the device (e.g. the PC
could have the IP address 10.1.100.152).
2. Enter the user name optimax, the password 1933 and click on the Login button
MO2-700ETH 5.2.02 Version
MO2-700ETH
10.1.1.1.1
255.0.0.0
IP receiver with one music
output and one paging output
R+D Department
10

Publicidad

loading