Descargar Imprimir esta página

Optimus M02-700RTH Manual De Instalación Y Funcionamiento página 12

Receptor ip con una salida de musica y una salida de avisos

Publicidad

Idiomas disponibles

Idiomas disponibles

7. SYSTEM ALARMS
The unit has a GENERAL FAULT indicator light (front yellow LED) that lights up when the unit receives one or more alarms from the
system or when it generates an alarm itself.
8. TECHNICAL SPECIFICATIONS
Ethernet communication
Audio outputs
Output contacts
Power supply
Consumption
LED indicators
Weight
Finishes
Dimensions (mm)
Accessories (not included)
MO2-700ETH 5.2.02 Version
MO2-700ETH
2 Ethernet connections (RJ45) A and B for redundant installations. IP Layer 3 & Layer 4
Network.
1 output channel for music, via RCA by means of RCA connector.
1 output channel for paging or paging/music, by means of RCA connector.
Maximum output level: 0 dBm
2 output contacts, configurable as dry contacts or referenced to ground. Max. DC load
current: 150 mA. Max. DC or AC peak load voltage: 350V.
MUS OUT CTRL. Activated when the music channel is active.
PAG OUT CTRL. Activated when the paging channel is active.
100-240 V.a.c.
10W
SIGNAL OUT: Indicates presence of analog signal at the outputs.
STREAMING: IP audio reception indicators.
POWER: Power supply.
GENERAL FAULT: System alarm indicator.
STARTING/RUNNING, indicating the status of the internal processor (starting up or
ready and running).
ETHERNET LINK and ACTIVITY.
1.8 Kg
Black painted iron RAL9005.
213.5 (width) x 44 (height) x 235 (depth)
Z-120 Single 19" rack mount kit.
Z-122 Double 19" rack mount kit.
Z-111 DIN rail mounting kit.
Z-110 Wall mounting kit.
IP receiver with one music
output and one paging output
R+D Department
12

Publicidad

loading